1500W surge clamp for 24V/48V telecom lines
The 1.5SMC36CA V7G: With a 30.8V reverse standoff voltage, it sits on a 24V or 48V telecom bus without conducting during normal operation, then clamps transients at 49.9V maximum to protect the downstream circuitry. The bidirectional configuration (single channel) means symmetrical clamping for AC signal pairs or bipolar supply rails — the same part works regardless of polarity, simplifying BOM management on a mixed-signal board.
DO-214AB SMC package and reflow assembly
The package is compatible with reflow soldering profiles typical for lead-free assembly.