Skip to main content
Infineon Technologies IKFW50N60DH3EXKSA1

Infineon IKFW50N60DH3EXKSA1 IGBT, 600V 40A TO-247-3

MPNIKFW50N60DH3EXKSA1
End of Life

Infineon TrenchStop IGBT, IKFW50N60DH3EXKSA1, Trench Field Stop, 600V Vces, 40A Ic, 130W, TO-247-3, Through Hole, -40°C to 175°C Tj.

$6.63Ref. price · indicative, final on quote
PackagingTO-247-3
RoHSROHS3 Compliant
SeriesTrenchStop™
Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

IKFW50N60DH3EXKSA1 specifications
ParameterValue
SeriesTrenchStop™
IGBT typeTrench Field Stop
Input typeStandard
MountingThrough Hole
Voltage - collector emitter breakdown600 V
Current - collector (Ic)40 A
Current - collector pulsed120 A
Power - max130 W
Operating temperature-40°C ~ 175°C (TJ)
PackageTube
Gate charge160 nC
CaseTO-247-3
Test condition400V, 40A, 8Ohm, 15V
Switching energy1.28mJ (on), 560µJ (off)
Td (on/off) @ 25°C21ns/174ns
Vce(on) (Max) @ vge, ic2.7V @ 15V, 40A
Reverse recovery time64 ns

Product details

600 V / 40 A TrenchStop IGBT in TO-247-3

The Infineon IKFW50N60DH3EXKSA1 is a 600 V, 40 A Trench Field Stop IGBT from the TrenchStop series, housed in a through-hole TO-247-3 package (PG-TO247-3-AI). It is a standard-input, single-switch device rated for 130 W maximum power dissipation and a 175 °C maximum junction temperature.

Conduction and switching — what the specs mean for the BOM

Switching energy is 1.28 mJ turn-on and 560 µJ turn-off at 400 V, 40 A, 8 Ω gate resistance, 15 V.

The 175 °C Tj max is the die limit, not the case temperature; the TO-247-3 package with a proper heatsink and thermal interface material is the expected mounting method. The 64 ns reverse recovery time on the co-packaged diode matters for bridge-leg shoot-through margin in half-bridge and full-bridge topologies.

If dual-sourcing is required, verify the TO-247-3 footprint compatibility with other 600 V, 40 A TrenchStop variants.

Frequently asked questions

What is the Vce(sat) of IKFW50N60DH3EXKSA1?

The maximum Vce(sat) is 2.7 V at 15 V gate drive and 40 A collector current. This is the on-state voltage drop used for conduction loss calculations in the thermal design.