What the standoff, breakdown, and clamping ratings mean
The 5.0SMDJ110A/TR13: The 5000W peak pulse power rating is the device's energy-absorption ceiling for a single 10/1000µs surge — this is the standard IEC 61000-4-5 characterization waveform, so the rating maps directly to the transient immunity test the end equipment is validated against.
Active sourcing posture
It ships in the standard tape-and-reel cut-tape format from YAGEO distribution.