What the ratings mean on the repair bench
The 1.5KE110CA/B: That 1500W rating tells you it can absorb a 10A surge while clamping the line to 152V — enough to protect a 94V DC rail from load-dump or inductive kickback without the part itself failing short.
The DO-201AA axial package (DO-27 equivalent) is a standard through-hole footprint — easy to hand-replace on a board with a soldering iron, no hot-air rework needed.