Skip to main content
Vishay VO3063 — Optoisolators

VO3063 Triac Optoisolator, 5300 Vrms, 600 V Off-State, 6-DIP

MPNVO3063
End of Life

VO3063 triac output optoisolator, 1 channel, 5300 Vrms isolation, 600 V off-state, zero-crossing, 1.5 kV/µs min dV/dt, 5 mA LED trigger, through-hole 6-DIP (0.300", 7.62mm), -55°C to 100°C, cUR/UR, RoHS3.

$1.55Ref. price · indicative, final on quote
Packaging6-DIP (0.300", 7.62mm)
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

VO3063 Technical Specifications
ParameterValue
Output typeTriac
Mounting typeThrough Hole
Voltage - isolation5300Vrms
Voltage - off state600 V
Voltage - forward (Vf)1.2V
Current - hold200µA (Typ)
Current - DC forward (If)60 mA
Current - LED trigger (Ift)5mA
Current - on state (It (RMS))100 mA
Operating temperature-55°C ~ 100°C
Approval agencycUR, UR
PackageTube
Case6-DIP (0.300\", 7.62mm)
Number of channels1
Static dV (dt)1.5kV/µs
Zero crossing circuitYes

Product details

5300 Vrms isolation — what it buys you

The VO3063 is a single-channel triac-output optoisolator from the VO306x family, designed for AC load switching where galvanic isolation between control and power domains is mandatory. Its 5300 Vrms isolation rating covers reinforced insulation requirements for industrial motor drives, solid-state relays, and medical equipment where the safety barrier must survive a mains transient without breakdown. The 600 V off-state voltage gives headroom for 240 VAC line switching with derating for inductive kickback.

Zero-crossing and dV/dt — the switching behaviour

The built-in zero-crossing circuit turns on the triac only near the AC voltage zero, which limits inrush current into capacitive or cold-filament loads and reduces conducted EMI. The minimum static dV/dt of 1.5 kV/µs means the output triac will not falsely trigger from fast-rising mains noise or commutating transients — a common failure in cheap optoisolators driving inductive loads like contactors or solenoid valves.

Temperature range and package

Rated for -55°C to 100°C operating ambient, the VO3063 spans military-temperature low end and industrial high end — usable in outdoor telecom cabinets, engine-bay electronics, or cold-chain storage controllers without a temperature grade compromise. The 6-DIP (0.300", 7.62mm) through-hole package is the standard footprint for optoisolators in this class; it suits wave-solder assembly and field replacement without reflow concerns. The hold current is 200 µA typical, so the triac stays latched through the AC zero-cross without dropout on lightly loaded lines.

Lifecycle and compliance

RoHS3 compliant and carries cUR/UR approvals for North American safety listings. This is a standard production part — no LTB risk, no need to stockpile for legacy BOMs.

Frequently asked questions

Can I replace MOC3063 with VO3063?

The VO3063 and MOC3063 are functionally similar — both are 1-channel, zero-crossing triac optoisolators in a 6-DIP package with 600 V off-state voltage. The VO3063 offers a higher isolation rating (5300 Vrms vs the MOC3063's typical 4170 Vrms) and a wider operating temperature range (-55°C to 100°C vs -40°C to 85°C). Pinout is identical, so it is a drop-in replacement where the higher isolation and temperature range are acceptable. Verify the LED trigger current threshold (5 mA max) matches your drive circuit.