Skip to main content
Vishay VO2223A-X007T — Discrete Semiconductors

VO2223A-X007T Vishay Triac Output Optoisolator, 5300Vrms

MPNVO2223A-X007T
End of Life

Vishay VO2223A-X007T power triac optoisolator, 1-channel, 600 V off-state, 5300 Vrms isolation, 8-SMD gull-wing package, surface mount, tape & reel.

$2.38Ref. price · indicative, final on quote
Packaging8-SMD (7 Leads), Gull Wing
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

VO2223A-X007T Technical Specifications
ParameterValue
Output typeTriac, Power
Mounting typeSurface Mount
Voltage - isolation5300Vrms
Voltage - off state600 V
Voltage - forward (Vf)1.4V (Max)
Current - hold25mA
Current - DC forward (If)50 mA
Current - LED trigger (Ift)10mA
Current - on state (It (RMS))1 A
Operating temperature-40°C ~ 85°C
Approval agencycUR, UR
PackageTape & Reel (TR); Cut Tape (CT)
Case8-SMD (7 Leads), Gull Wing
Number of channels1
Static dV (dt)210V/µs (Typ)
Zero crossing circuitNo

Product details

Mains-isolated triac drive in an 8-SMD package

The VO2223A-X007T is a 1-channel power triac optoisolator from Vishay that drives low-current AC loads from a logic-level control side with 5300 Vrms galvanic isolation. The 600 V off-state blocking voltage covers 240 VAC mains with margin for nominal line transients, while the 1 A RMS on-state current suits solenoid valves, small fans, or lamp loads where a discrete triac would need extra gate drive.

Snubberless commutation and random-phase firing

A typical static dV/dt of 210 V/µs means the output triac resists false turn-on from fast-rising mains transients — snubberless operation is viable in many resistive loads, saving board space and component count. There is no zero-crossing circuit, so the triac fires at any phase angle; this allows phase-angle control for heater dimming or soft-start but injects higher inrush at turn-on compared to a zero-crossing part. The LED trigger current (Ift) is 10 mA max, with a forward voltage of 1.4 V max and a 50 mA DC forward current limit. The 25 mA hold current (Ih) sets the minimum load needed to keep the triac latched once triggered — below this, the output drops out at zero-cross, so check the load current at the lowest operating point.

Industrial temperature and approvals

The 8-SMD gull-wing package suits standard surface-mount assembly; the 7-lead variant leaves one lead omitted for creepage distance on the output side. Supplied in tape-and-reel or cut-tape options for volume or prototype runs.

Frequently asked questions

Does VO2223A-X007T have zero-crossing detection?

No — the zero-crossing circuit is marked 'No'. The triac fires at the instant the LED current exceeds Ift, enabling phase-angle control but requiring attention to inrush at turn-on.

What approvals does the VO2223A-X007T carry?

It carries cUR and UR approvals, covering North American safety standards for reinforced insulation.