Unitrode UC2843ANNTR — Analog & Data Acquisition
Technical Documents PDF / CAD
RoHS Compliant · Lead-Free EIA-481 Standard
Unitrode / Analog & Data Acquisition

Unitrode UC2843ANNTR

MPN UC2843ANNTR
Active Spot Stock · 24-48h Dispatch 100% Original Sealed

UC2843 SWITCHING CONTROLLER

In Stock: 21,377 pcs
MOQ: 20 pcs
Logistics: DHL / FedEx DAP (Global Express · 3-7d) Russia & CIS DDP (Door-to-Door Cleared)
Dispatch: Shenzhen / HK
Unit Price (USD)
$0.60 / pc
Direct Purchase Ready
Volume Pricing Breaks Confirmed upon quotation
1+ pcs
$0.60
10+ pcs
$0.54
30+ pcs
$0.49
100+ pcs
$0.44
500+ pcs
$0.41
1,000+ pcs
$0.39
Working on a production BOM or have a target unit price? Submit Target Price
Buy Now

$0.54 / ea · total $10.80

21,377 in stock — maximum per order · MOQ 20 · 3–4 days lead time

$0.49 / ea from 30 pcs

Upload Full BOM List
[SPEC] Essential Parameters Snapshot Full Specifications (16)
Package / Case 8-DIP (0.300", 7.62mm)
Supply Voltage 7.6V ~ 30V
ALT
Facing long factory lead times or allocation on UC2843ANNTR? Verified pin-compatible alternatives available with active Shenzhen stock and 100% solder-ready footprint match.

Full Technical Specifications

16 Parameters
UC2843ANNTR specifications
Parameter / AttributeSpecification / Value
Output typeTransistor Driver
MountingThrough Hole
Voltage - supply (Vcc (Vdd))7.6V ~ 30V
Frequency - switchingUp to 500kHz
I/O channels1
Output phases1
Duty cycle96%
Operating temperature-40°C ~ 85°C (TA)
PackageBulk
FunctionStep-Up, Step-Down, Step-Up/Step-Down
TopologyBoost, Buck, Flyback, Forward
Clock syncNo
Case8-DIP (0.300\", 7.62mm)
Control featuresFrequency Control
Output configurationPositive, Isolation Capable
Synchronous rectifierNo
100% Footprint Match · Solder-Ready (No PCB Redesign Needed)

Need Stock or a Drop-in Second-Source for UC2843ANNTR?

Package: DIP-8 / SOIC-8 · Pin-compatible replacements with immediate Shenzhen spot stock

Footprint Match 98%
Supply Chain & Allocation Reality:

The UC384x family is the current-mode PWM controller inside a generation of offline switching supplies, adapters, chargers and ATX standby rails - an 8-pin part that appears in repair in every country, and the most-fitting-wrong-part in power-supply benches. The four suffixes are not interchangeable decorations: the start-up threshold is either 16V (3842/3844, offline rails) or 8.4V (3843/3845, low-voltage rails), and the maximum duty cycle is either full (3842/3843) or 50 percent (3844/3845, for half-bridge and push-pull topologies). The wrong suffix shows up as a supply that will not start, or a transformer that saturates.

Verified Pin-Compatible Replacements (4 verified alternatives)

UC3843 TI / onsemi / STMicroelectronics DIP-8 / SOIC-8
Pin-to-Pin (Minor Clock/Init Tuning)
Availability & Target Pricing:

The Low-Voltage Start Sibling

Shenzhen Spot Stock (24-48h Dispatch)

Electrical & Core Specs:

Identical current-mode PWM engine with the UVLO window shifted down: 8.4V turn-on / 7.6V turn-off against 16V / 10V for the UC3842. Full duty cycle, 500kHz class oscillator, 5V reference, totem-pole output.

Works from lower VCC rails - the part for DC-DC converters running from 12V and 24V buses.

Compatibility & Drop-In Notes: In an offline supply fitted as a substitute for a 3842, the supply can attempt to start at a lower rail voltage - usually it simply works off the aux winding, but brown-out behavior and start-up resistor design were sized around 16V. Do not swap in this direction as routine repair policy; match the original suffix.
Package & Solder Footprint: DIP-8 / SOIC-8, pin-identical across the family.
Shenzhen Warehouse Stock & MOQ: Deep multi-fab stock; the DC-DC builders part.
UC3844 TI / onsemi / STMicroelectronics DIP-8 / SOIC-8
Pin-to-Pin (Minor Clock/Init Tuning)
Availability & Target Pricing:

The 50% Duty Offline Sibling

Shenzhen Spot Stock (24-48h Dispatch)

Electrical & Core Specs:

Same 16V UVLO as the 3842 with the output limited to 50 percent maximum duty by an internal toggle flip-flop - the part for half-bridge and push-pull offline converters.

16V turn-on / 10V turn-off; the offline start-up window.

Compatibility & Drop-In Notes: Fitting a 3844 where a 3842 belongs halves the maximum duty and the converter underperforms or drops out; fitting a 3842 where a 3844 belongs lets a push-pull transformer see full duty - saturation and blown switches. The suffix is functional, not cosmetic.
Package & Solder Footprint: Same 8-pin body and pin assignment.
Shenzhen Warehouse Stock & MOQ: Stocked as the half-bridge part; keep the four suffixes separated in the drawer.
UC3845 TI / onsemi / STMicroelectronics DIP-8 / SOIC-8
Pin-to-Pin (Minor Clock/Init Tuning)
Availability & Target Pricing:

Low Start and 50% Duty Combined

Shenzhen Spot Stock (24-48h Dispatch)

Electrical & Core Specs:

The fourth quadrant of the matrix: 8.4V UVLO with the 50 percent duty flip-flop - low-voltage push-pull and half-bridge converters.

8.4V turn-on / 7.6V turn-off.

Compatibility & Drop-In Notes: Listed to complete the ladder; substitutions across the family must carry both numbers - threshold AND duty - or the repair reintroduces the failure.
Package & Solder Footprint: Same DIP-8 / SOIC-8 pinout.
Shenzhen Warehouse Stock & MOQ: Stocked as part of the four-suffix kit for supply repair benches.
UC2842 TI / onsemi DIP-8 / SOIC-8
100% Drop-in (Zero Code Change)
Availability & Target Pricing:

The Industrial-Temperature Grade

Shenzhen Spot Stock (24-48h Dispatch)

Electrical & Core Specs:

Electrically the same controller in the UC284x (industrial temperature) grade against the UC384x (commercial) - same thresholds and duty per suffix digit.

Same UVLO scheme; the 2 in the prefix is temperature range, not function.

Compatibility & Drop-In Notes: When a supply runs hot or outdoors, the industrial grade is the honest replacement. Reading the prefix as function misleads - only the last digit sets threshold and duty.
Package & Solder Footprint: Same body and pinout across all temperature grades.
Shenzhen Warehouse Stock & MOQ: Stocked for industrial service work; verify the prefix on the marking.
Buyer & Quality Checklist for Sourcing Alternatives
  • Read two numbers before any substitution: UVLO start threshold (3842/3844 = 16V, 3843/3845 = 8.4V) and maximum duty (3842/3843 = full, 3844/3845 = 50 percent). Wrong threshold = will not start or starts on brown-out; wrong duty = underperformance or transformer saturation.
  • On the 50-percent parts (3844/3845) the oscillator runs at twice the switching frequency by design - when repairing, set RT/CT for the doubled value or everything downstream shifts.
  • The start-up network is part of the chip choice: offline designs charge VCC through a resistor from the high rail, and the aux winding must take over before the 10V turn-off. Fitting a lower-threshold suffix changes when that handover happens.
  • Current-sense input tolerances and leading-edge blanking are fixed in silicon - if a repair needed a snubber change to behave, suspect the wrong suffix or a clone die before redesigning the sense network.
  • The clone market here is deep: relabeled no-name dies pass DC tests and drift on frequency. For fleet repairs, keep verified lots and photograph the markings.
  • UC184x / UC284x / UC384x are temperature grades of the same function - use the industrial grade for hot enclosures rather than substituting down.
Frequently Asked Technical Questions

Q: What is the difference between UC3842 and UC3843?

A: The start-up threshold: UC3842 turns on at 16V (offline supplies), UC3843 at 8.4V (low-voltage DC-DC). Everything else - including full duty capability - is the same. Match the original suffix so the start-up network behaves as designed.

Q: Can I use a UC3842 where a UC3844 was fitted?

A: No - the 3844 is the 50-percent-duty part used in push-pull and half-bridge designs. A full-duty part in that socket can saturate the transformer and destroy the switching devices. The last digit encodes the duty limit; respect it.

Q: Why does my supply not start after a PWM chip replacement?

A: Check the suffix first: a 3843/3845 fitted into an offline design starts at 8.4V and the bias winding handover may misbehave, and a 16V part in a low-voltage design never reaches its threshold. Wrong-threshold swaps are the most common self-inflicted repair failure on this family.