ROHM Semiconductor BD45422G-TR — Microcontrollers & Processors (MCU / MPU / DSP)

ROHM BD45422G-TR Voltage Detector, 4.2V Threshold

MPNBD45422G-TR
End of Life

ROHM BD45xxx series voltage detector, BD45422G-TR, 4.2V threshold, active-low open-drain output, 180ms minimum reset timeout, -40°C to 105°C operating temperature, SC-74A (SOT-753) surface-mount package.

$0.8Ref. price · indicative, final on quote
PackagingSC-74A, SOT-753
RoHSROHS3 Compliant
SeriesBD45xxx
Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

BD45422G-TR specifications
ParameterValue
TypeVoltage Detector
SeriesBD45xxx
MountingSurface Mount
Voltage - threshold4.2V
Number of voltages monitored1
Operating temperature-40°C ~ 105°C (TA)
ResetActive Low
OutputOpen Drain or Open Collector
PackageTape & Reel (TR); Cut Tape (CT)
Reset timeout180ms Minimum
CaseSC-74A, SOT-753

Product details

4.2V threshold — what it monitors

The ROHM BD45422G-TR is a single-channel voltage detector with a 4.2V threshold, designed to assert a reset when the monitored supply drops below that level. With an active-low, open-drain output, it pulls the reset line low during undervoltage and releases it after the supply recovers and the 180ms minimum reset timeout expires. This part is from the BD45xxx series and comes in an SC-74A (SOT-753) package for surface-mount assembly.

180ms reset timeout — why it matters

The 180ms minimum reset timeout gives the system power rail time to stabilize before the processor or logic starts executing code. This prevents spurious boot-ups during supply glitches or slow ramp-up. For a 5V rail, the 4.2V threshold provides roughly 16% undervoltage detection margin — enough to catch a sagging supply before logic errors occur, but not so tight that normal ripple triggers false resets.

Open-drain output — wired-OR flexibility

The open-drain (open-collector) output lets you connect multiple voltage detectors to a single shared pull-up resistor, creating a wired-OR reset bus. This is useful in multi-rail systems where any rail dropping out should assert a global reset. The output is active low, so the reset line is held low during the fault and released high after the timeout.

The SC-74A package (SOT-753 footprint) is a common 5-pin small-outline transistor package, easy to place and reflow.

ROHM lists the BD45422G-TR as Active. The open-drain output and 4.2V threshold are fixed — no pin-strapping options.

Frequently asked questions

What is the reset timeout of the BD45422G-TR?

The reset timeout is a minimum of 180ms. After the monitored voltage rises above the 4.2V threshold, the output stays low for at least 180ms before releasing high.

Is the BD45422G-TR compatible with 3.3V systems?

No — the threshold is 4.2V, designed to monitor a 5V rail. It will not assert a reset on a 3.3V supply because the threshold is above the normal operating voltage. For 3.3V monitoring, look at the BD49xxx series (e.g., BD4929G-TR) with lower thresholds.

What is a direct replacement or equivalent for BD45422G-TR?

The closest functional peer is the BD4929G-TR from the BD49xxx series, which also offers an active-low reset but uses a push-pull output instead of open-drain. The BD4929G-TR has a different threshold voltage — verify the trip point for your rail. No pin-compatible drop-in exists with the same 4.2V open-drain combination.