Omron E3T-FT11 — Interface & Transceivers

Omron E3T-FT11 Through-Beam Sensor, 500 mm, NPN, IP67

MPNE3T-FT11
Active

Omron E3T series, through-beam photoelectric sensor, E3T-FT11, NPN open-collector Light-ON output, 12 V supply, 500 mm sensing distance, IP67, red LED 650 nm, 1 ms response, cable connection, -25°C to 55°C.

$144.36Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

E3T-FT11 Technical Specifications
ParameterValue
SeriesE3T
Connection_methodCable
Operating temperature high-25°C to 55°C
Ip_ratingIP67
Output_typeNPN - Open Collector/Light-ON
Light_sourceRed (650nm)
Package_typeBulk
Sensing_typeThrough-Beam
Response_time_ms1
Supply_voltage_v12
Sensing_distance_max_mm19.685

Product details

Through-beam at 500 mm — what it means on the line

The Omron E3T-FT11 is a through-beam photoelectric sensor that breaks a red 650 nm beam across a 500 mm gap. When an object interrupts the beam, the NPN open-collector output switches Light-ON — meaning the output is on when the beam is uninterrupted, off when blocked. That 1 ms response time keeps up with fast-moving parts on a packaging or conveyor line, and the IP67 rating means it handles washdown without a second enclosure.

Mounting and wiring — what to expect

Cable connection, no connector — plan for a gland or strain relief at the panel entry. The -25°C to 55°C operating range covers most indoor factory floors but not freezer or outdoor summer extremes. Supply it with 12 VDC; the NPN output sinks to ground, so verify your load is between the output and the positive rail.

Frequently asked questions

What is the difference between E3T-FT11 and E3T-FT12?

The E3T-FT11 is NPN Light-ON; the E3T-FT12 is NPN Dark-ON. Both are through-beam at 500 mm with the same mechanicals, so swapping them changes the logic sense, not the mounting.

Will the E3T-FT11 drop into a panel wired for E3T-FT12?

Yes — same through-beam range, same cable, same IP67. The only difference is the output logic: E3T-FT11 switches on when the beam is uninterrupted (Light-ON), while E3T-FT12 switches on when the beam is blocked (Dark-ON). No mechanical rework needed.