Analog Devices MAX704CSA+ — Power Management (PMIC / Gate Driver)

MAX704CSA+ Battery Backup Circuit, 4.4V Threshold

MPNMAX704CSA+
End of Life

Maxim Integrated MAX704CSA+ Battery Backup Circuit, 1-Channel Supervisor, Active Low Reset, Push-Pull Output, 4.4V Threshold, 140ms Reset Timeout, 8-SOIC Package, Tube.

$10.88Ref. price · indicative, final on quote
Packaging8-SOIC (0.154", 3.90mm Width)
RoHSROHS3 Compliant
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

MAX704CSA+ specifications
ParameterValue
TypeBattery Backup Circuit
MountingSurface Mount
Voltage - threshold4.4V
Number of voltages monitored1
Operating temperature0°C ~ 70°C (TA)
ResetActive Low
OutputPush-Pull, Totem Pole
PackageTube
Reset timeout140ms Minimum
Case8-SOIC (0.154\", 3.90mm Width)

Product details

Supervisor for 5V rails — the 4.4V threshold catches brownout before the processor glitches

The MAX704CSA+ is a 1-channel battery-backup supervisor from Maxim Integrated, monitoring a single voltage rail with a 4.4V threshold. The 4.4V threshold is set for a nominal 5V supply — it triggers before the rail falls below the minimum operating voltage of most 5V logic and MCUs, giving the system a clean reset boundary rather than letting the processor run on a decaying rail.

The MAX704CSA+ drives an active-low reset output with a push-pull (totem-pole) stage. Unlike an open-drain output, this does not require an external pull-up resistor to VCC — the output swings rail-to-rail and drives the reset line directly into the processor's reset input. The 140ms minimum reset timeout gives the supply rail and oscillator time to stabilise before the processor is released from reset. This suits microcontrollers with slow-start PLLs or external crystal oscillators that need tens of milliseconds to reach steady-state frequency.

Active production, ROHS3 compliant — no last-time-buy pressure

The commercial temperature grade (0°C to 70°C) covers indoor equipment and most industrial enclosures without active cooling.