Differential output and 60 mA per channel
The differential output stage delivers up to 60 mA per channel, enough to drive small relays, indicator LEDs, or the input of a downstream comparator without a separate buffer. The output swing is not rail-to-rail — expect headroom of roughly 1.5 V from each rail at moderate load. If the load requires swinging within 100 mV of the supply, a rail-to-rail output type such as the TS924IYPT is the alternative to evaluate.
For dual-sourcing resilience, the LM258AWDT (dual) and MC3303DT (quad) are electrically similar but carry a 105°C maximum temperature rating — verify the temperature grade before substituting into a 125°C environment. The TS924IYPT shares the same 125°C rating and AEC-Q100 qualification, adds rail-to-rail output, but at a higher GBW of 4 MHz and a different supply minimum of 2.7 V.