Skip to main content
3RT20182BB41

Siemens 3RT20182BB41 SIRIUS 3RT2 Contactor 24VDC 16A Spring Clamp

MPN3RT20182BB41Compare · similar
Active · In production

The Siemens 3RT20182BB41 is a SIRIUS 3RT2 S00-frame contactor with three normally-open power poles rated 16A per pole, switched via a 24VDC coil consuming 4W (166.7 mA). Spring-clamp terminals speed up panel assembly by removing torque-check steps. One normally-open auxiliary contact ships pre-installed. Operating range spans 25°C to 60°C. Switching voltage reaches 690VAC maximum. Base product number is 3RT2018.

PackagingBulk
Volume pricing1+ $180.36000
StockOut of Stock

Specifications

3RT20182BB41 Technical Specifications - Column 1
ParameterValue
Series3RT2
MountingChassis Mount, DIN Rail
Rohs StatusROHS3 Compliant
Coil Voltage24VDC
Coil Resistance144Ohms
Termination StyleSpring Terminal
Must Operate Voltage19.2 VDC
Contact Rating (current)16 A
3RT20182BB41 Technical Specifications - Column 2
ParameterValue
FeaturesAuxiliary Contacts
Coil Power4W
Coil Current166.7 mA
Contact Form3PST-NO (3 Form A)
Switching Voltage690VAC - Max
Base Product Number3RT2018
Operating temperature25°C ~ 60°C

Product details

Siemens 3RT20182BB41 S00 Power Contactor

The Siemens 3RT20182BB41 is a three-pole, S00-frame power contactor with a 24 VDC magnet coil, rated 16 A per pole and configured with one normally-open auxiliary contact (1NO). The suffix "BB" in the 3RT ordering code denotes the spring-clamp terminal execution, which is a common panel-builder preference for tool-free wiring in DIN-rail or chassis-mount arrangements.


Key Specifications

ParameterValue
Coil Voltage24 VDC
Must Operate Voltage19.2 VDC
Coil Power4 W
Coil Current166.7 mA
Coil Resistance144 Ω
Contact Form3PST-NO (3 Form A)
Contact Rating (Current)16 A
Base Product Number3RT2018
Mounting TypeChassis Mount, DIN Rail
EncapsulationBulk
FeaturesAuxiliary Contacts

Contact Arrangement and Coil Class

The contactor provides three main power poles (3PST-NO) for switching AC or DC motor loads, plus one integrated auxiliary contact. The must-operate voltage of 19.2 VDC represents 80 % of the rated coil voltage, which is a standard pickup threshold for DC-operated contactors in industrial control circuits.

Coil Impedance and DC Drop-Out Behavior

Because the coil draws a continuous 166.7 mA at 24 VDC (4 W steady-state), the engineer should account for:

  • Drop-out reliability: DC coils require a defined minimum voltage to hold closed. The record lists the must-operate threshold; any voltage sag below that level may cause dropout during brownout conditions.
  • Coil resistance of 144 Ω provides a reference for in-circuit continuity checking.

Auxiliary Contact Function

The built-in 1NO auxiliary contact is suitable for signaling the contactor's status to a PLC input module or an indicator circuit. The spring-terminal execution on the BB suffix generally applies to both power and auxiliary terminals, simplifying field wiring.


Installation and Cabinet Integration

  • S00 size (Sirius Mini) is one frame size smaller than the standard S2, fitting compact enclosures where panel space is constrained.
  • Mounting options listed are chassis mount and DIN rail (35 mm top-hat rail per EN 60715), which are typical for motor branch panels.
  • The contactor's DC coil requires a clean, regulated 24 VDC supply; engineers should verify supply ripple and short-circuit coordination if the coil feed shares a bus with other DC loads.

In-Catalog Comparison Rows (Reader Qualification Required)

The following rows share the same base product number, coil power, current rating, and mounting type. Differences in coil voltage, contact arrangement, or encapsulation type are noted; the reader must perform their own application qualification before substitution.

MPNCoil VoltageMain ContactEncapsulationMust Operate Voltage
3RT20182BB41 (primary)24 VDC3PST-NO + 1NO auxBulk19.2 VDC
3RT20182BB4224 VDC3PST-NO + 1NC auxBulk19.2 VDC
3RT20182BB410CC024 VDC3PST-NO + 1NO auxBox19.2 VDC
3RT20182BB420CC024 VDC3PST-NO + 1NC auxBox19.2 VDC
3RT20182BF41110 VDC3PST-NO + 1NO auxBox88 VDC
3RT20182BE4160 VDC3PST-NO + 1NO auxBox48 VDC
3RT20182BW4148 VDC3PST-NO + 1NO auxBox38.4 VDC
3RT20182BM41220 VDC3PST-NO + 1NO auxBox176 VDC
3RT20182BB443MA024 VDC2NO/2NC aux contact blockBox19.2 VDC

Why Each Variant Differs

  • 3RT20182BB42 replaces the auxiliary normally-open contact with a normally-closed (NC) contact — appropriate when the auxiliary is wired for a trip or interlock function.
  • 3RT20182BF41 / BE41 / BW41 / BM41 target different DC supply systems; the coil voltage varies from 48 VDC up to 220 VDC while maintaining the same 4 W coil power class.
  • 3RT20182BB443MA0 adds a dedicated 2NO/2NC auxiliary contact block, increasing signaling flexibility at the cost of a larger termination footprint.
  • Box vs. Bulk encapsulation refers to the supplied packaging format; no electrical difference is implied.

What buyers are searching for

Buyers searching the 3RT20182BB41 are comparing S00 frame contactors for motor starter retrofits, checking whether 1NO auxiliary contact logic fits their existing 3RU2 overload wiring scheme, and verifying spring-clamp compatibility with panel labor constraints. Some are cross-referencing legacy 3RT1 part numbers to confirm form-fit-function replacement with the newer 3RT2 generation.

Engineering notes

  • Coil inrush at 166.7 mA draws ~4W when energized; confirm PLC output module rating can sustain this across all auxiliary loads.
  • Must-operate voltage of 19.2 VDC gives 80% drop-out margin at nominal 24VDC supply; verify line sag under load does not breach this threshold.
  • 3RT2 series uses the same mechanical mounting footprint as 3RT1 legacy units; panel cutouts typically align without modification.
  • Operating temperature ceiling of 60°C may require cabinet ventilation in sealed enclosures with multiple heat sources.

When to choose this part

  • Choose this unit when your circuit requires a normally-open auxiliary contact for status indication or interlock, and you need 24VDC coil with spring-clamp wiring in a tight S00 form factor.
  • Switch to 3RT20182BB42 if the auxiliary must be normally-closed (1NC) for your feedback logic—all other electrical parameters remain identical.
  • Upgrade to 3RT20182BB443MA0 when two auxiliary contacts (2NO/2NC) are needed, but note this variant uses screw terminals and may affect your wiring schedule.
  • Confirm DIN rail clearance beneath the contactor before mounting; spring-clamp access requires side clearance for the release lever.

Limitations & things to verify

  • Operating temperature ceiling of 60°C constrains use in high-ambient cabinet environments without forced ventilation.
  • Must-operate voltage of 19.2 VDC means the coil may not pull in reliably if 24VDC supply sags below this threshold under heavy load.
  • Spring-clamp termination requires side clearance for lever actuation; verify panel layout permits access during maintenance.
  • Only one auxiliary contact included; applications requiring 2NO/2NC logic need a different variant.

Frequently asked questions

Order multiples for 3RT20182BB41?

3RT20182BB41: Evaluation quantities are usually workable—confirm on RFQ.. If your BOM needs odd multiples, note it before pricing.

Where does 3RT20182BB41 usually fit electrically?

Use category + headline specs here as a first screen only. Final fit needs your loads, protection, and environment.

What does this page list for “Contact Form” on 3RT20182BB41?

The storefront table shows **Contact Form**: 3PST-NO (3 Form A). Treat it as a catalog snapshot—re-verify safety-critical ratings on the current manufacturer datasheet.

Compatible lines besides 3RT20182BB41?

Substitution is evidence-led: compare the same keys your schematic cares about, then validate in hardware.

Catalog value for “Mounting” (3RT20182BB41)?

**Mounting** is recorded as **Chassis Mount, DIN Rail** for 3RT20182BB41. If your drawing disagrees, the datasheet wins.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (8 parts) · columns 2+ sorted by Hub similarity to 3RT20182BB41

Technical resources

Lifecycle: ActiveRoHS: ROHS3 Compliant