3RT20151AB01

3RT20151AB01 Contactors (Electromechanical) | siemens

MPN3RT20151AB01Compare · similar
Active · In production

3RT20151AB01 (siemens) Contactors (Electromechanical). Series 3RT2; Package Bulk; Features Auxiliary Contacts. RFQ for MOQ and lead time.

PackagingBulk
Volume pricing1+ $79.25000
StockOut of Stock

Specifications

3RT20151AB01 Technical Specifications - Column 1
ParameterValue
RoHSROHS3 Compliant
StatusActive
FeaturesAuxiliary Contacts
Coil Voltage24VAC
Operate Time35 ms
Switching Voltage690VAC - Max
Base Product Number3RT2015
Operating temperature25°C to 60°C
3RT20151AB01 Technical Specifications - Column 2
ParameterValue
Series3RT2
PackageBulk
MountingChassis Mount, DIN Rail
Contact Form3PST-NO (3 Form A)
Release Time14 ms
Termination StyleScrew Terminal
Must Operate Voltage20.4 VAC
Contact Rating (Current)7 A

Product details

Siemens 3RT20151AB01 | S00 Frame 7 A Contactors

Coil and Control Trade-offs for 3RT2015 S00 Contactors

  1. Must-operate voltage 20.4 VAC — ensures pull-in below 85% of nominal coil voltage, but limits use in severely undervoltage conditions common with long control runs.
  2. Operate time 35 ms — adequate for general motor startup sequencing; however, faster logic circuits or safety-related de-energization may require supplementary intermediate relays.
  3. Operating temperature 25°C–60°C — not suited for unventilated enclosures in high-ambient installations without thermal derating; Siemens specifies 7 A AC-3 at 60°C with standard ventilation.
  4. Bulk vs. box packaging — seed is bulk-packed; alternates 3RT20151AB011AA0 and 3RT20151AB012AA0 ship in box packaging, affecting inventory staging for service-stock workflows.

Contact Configuration Comparison

The seed (3RT20151AB01) is one of eight S00-frame variants sharing identical 7 A AC-3 ratings, chassis/DIN mounting, and 35 ms operate time. Coil voltage is the primary differentiator. Voltage selection must account for must-operate thresholds and control-circuit architecture.

Parameter3RT20151AB013RT20151AB011AA03RT20151AB012AA03RT20151AB02
Coil Voltage24 VAC24 VAC24 VAC24 VAC
Contact Form3PST-NO3PST-NO3PST-NO3PST-NO
Contact Rating7 A7 A7 A7 A
MountingChassis, DIN RailChassis, DIN RailChassis, DIN RailChassis, DIN Rail
EncapsulationBulkBoxBoxBulk
Similarity1.01.01.0

Additional alternates with differing coil voltages (all S00 frame, 7 A, chassis/DIN mount):

  • 3RT20151AV01 — 400 VAC coil (must-operate 340 VAC)
  • 3RT20151AU01 — 240 VAC coil (must-operate 204 VAC)
  • 3RT20151AH01 — 48 VAC coil (must-operate 40.8 VAC)
  • 3RT20151AD01 — 42 VAC coil (must-operate 35.7 VAC)

Readers must verify coil voltage compatibility against their control-circuit nominal voltage and acceptable voltage-drop budget before specifying any variant.

Why these are similar: All eight parts share the same base number 3RT2015, identical 7 A contact rating, identical mounting provisions, and the S00 frame mechanical envelope. Differences are limited to coil voltage and packaging type.


Engineering Verification Checklist

  • Confirm control-circuit nominal voltage matches coil rating (24 VAC for seed).
  • Verify must-operate voltage (20.4 VAC) is below worst-case control-circuit voltage under load.
  • Check panel ambient temperature and ventilation; derate if > 50°C enclosure temperature.
  • Validate AC-3 utilization category suits motor load (7 A, 3-phase nominal).
  • Confirm DIN rail or chassis mounting compatible with existing enclosure layout.
  • Verify auxiliary contact configuration (1NO on seed) meets status-feedback or interlock requirements.
  • Confirm packaging (bulk vs. box) aligns with inventory and service-stock policies.
  • Review coil power draw (listed on alternate records as 24.3 VA) against control-transformer or supply capacity.

Frequently asked questions

Lead time / allocation notes for 3RT20151AB01 (3RT20151AB01)?

siemens line card data is a snapshot. Ships quickly when in stock; otherwise lead time follows distributor or factory lots. Lock dates on your PO or distributor confirmation.

What can substitute for 3RT20151AB01 if supply tightens?

We narrow candidates from footprint, voltage/current class, and approvals visible on this page. Any change still needs your datasheet review and hardware qualification—not a guaranteed substitute from storefront text.

What does this page list for “Operate Time” on 3RT20151AB01?

The storefront table shows **Operate Time**: 35 ms. Treat it as a catalog snapshot—re-verify safety-critical ratings on the current manufacturer datasheet.

What is the minimum order quantity (MOQ) for 3RT20151AB01?

MOQ for 3RT20151AB01: Evaluation quantities are usually workable—confirm on RFQ.. Pilot builds can often start smaller—state your target annual usage in the RFQ.

Catalog value for “Must Operate Voltage” (3RT20151AB01)?

**Must Operate Voltage** is recorded as **20.4 VAC** for 3RT20151AB01. If your drawing disagrees, the datasheet wins.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (8 parts) · columns 2+ sorted by Hub similarity to 3RT20151AB01

Technical resources

Lifecycle: ActiveRoHS: ROHS3 Compliant