3RT20161AF02 Technical Specifications - Column 1
ParameterValue
RoHSROHS3 Compliant
StatusActive
FeaturesAuxiliary Contacts
Coil Power27VA
Contact Form3PST-NO (3 Form A)
Release Time14 ms
Termination StyleScrew Terminal
Must Operate Voltage93.5 VAC
Contact Rating (Current)9 A
3RT20161AF02 Technical Specifications - Column 2
ParameterValue
Series3RT2
PackageBulk
MountingChassis Mount, DIN Rail
Coil Voltage110VAC
Operate Time35 ms
Switching Voltage690VAC - Max
Base Product Number3RT2016
Operating temperature25°C to 60°C

Product details

Siemens 3RT20161AF02 S00 Contactor — 9 A, 110 VAC Coil

Catalog Identity and S00 Frame Context

The 3RT20161AF02 is a Siemens SIRIUS 3RT2 series electromechanical contactor in the S00 (Size 00) frame. The part carries a 9 A contact rating at the stated coil voltage of 110 VAC, with auxiliary contacts listed under Features. The Base Product Number shared across this group is 3RT2016, indicating the 9 A current class within the SIRIUS S00 modular system.

Key Selection Trade-offs

  1. Coil voltage class: The primary part specifies 110 VAC; alternates in this group span 24 VAC through 400 VAC. Coil voltage must match the control circuit feeding the contactor — selecting a part with a different coil voltage class requires a separate catalog entry; these cannot be interchanged without rewiring the coil circuit.

  2. Must-operate voltage margin: The seed specifies a must-operate voltage of 93.5 VAC, meaning the coil is guaranteed to pull in at or above that level across the stated operating temperature range of 25°C to 60°C. If the available control voltage is marginal or poorly regulated, confirm the must-operate threshold is comfortably exceeded.

  3. Auxiliary contact configuration: All parts in this group list "Auxiliary Contacts" under Features. The title suffix indicates 1NC (one normally closed auxiliary); however, the Contact Form field records 3PST-NO (three normally-open poles) — a discrepancy in the source catalog data that the reader should clarify against the Siemens ordering code or datasheet before finalizing the auxiliary function.

  4. Encapsulation / packaging: The seed ships in Bulk encapsulation; several alternates are listed as Box. Packaging may affect inventory handling and unit-of-issue in procurement.

  5. Coil power draw: The seed lists 27 VA; several alternates list 24.3 VA. Inrush and holding coil power affect VA sizing for the control transformer or power supply driving the coil — a 10% difference in coil VA may be material in tightly sized control circuits.

Technical Parameters

ParameterValue
Base Product Number3RT2016
Contact Rating (Current)9 A
Coil Voltage110 VAC
Must Operate Voltage93.5 VAC
Coil Power27 VA
Contact Form3PST-NO (3 Form A)
Operate Time35 ms
Operating Temperature25°C ~ 60°C
Mounting TypeChassis Mount, DIN Rail
EncapsulationBulk
FeaturesAuxiliary Contacts
MfrSiemens

Similar Catalog Parts (Catalog Screening Only)

The table below presents in-catalog peers sharing the same base product number and 9 A rating. These are not approved substitutes; the reader must perform their own qualification before selecting any alternate for a given application.

MPNCoil VoltageCoil PowerMust OperateContact RatingSimilarity
3RT20161AF02 (primary)110 VAC27 VA93.5 VAC9 A
3RT20161AF01110 VAC27 VA93.5 VAC9 A1.0
3RT20161AF011AA0110 VAC24.3 VA93.5 VAC9 A1.0
3RT20161AB0224 VAC27 VA20.4 VAC9 A1.0
3RT20161AH0248 VAC24.3 VA40.8 VAC9 A1.0
3RT20161AD0242 VAC24.3 VA35.7 VAC9 A1.0
3RT20161AP02230 VAC27 VA195.5 VAC9 A1.0
3RT20161AQ02380 VAC24.3 VA323 VAC9 A1.0
3RT20161AV02400 VAC24.3 VA340 VAC9 A1.0

Why Each Alternate Is Catalog-Similar

  • 3RT20161AF01 shares the identical coil voltage (110 VAC), must-operate voltage, coil power, and contact rating. The title indicates 1NO rather than 1NC auxiliary; the reader should verify auxiliary contact type against the intended safety or interlocking function.

  • 3RT20161AF011AA0 matches on coil voltage and contact rating but lists a slightly lower coil power (24.3 VA vs. 27 VA) and ships in Box encapsulation rather than Bulk. The parametric similarity score reflects this minor power rating difference.

  • 3RT20161AB02 is the 24 VAC coil variant within the same 3RT2016 family. Coil voltage class is the primary differentiator; must-operate voltage scales proportionally (20.4 VAC). These are distinct control-circuit selections, not interchangeable at the coil.

  • 3RT20161AH02 (48 VAC) and 3RT20161AD02 (42 VAC) represent lower-voltage coil options in the same series. Both share the same contact rating and mounting type; coil power and must-operate thresholds shift with the voltage class.

  • 3RT20161AP02 (230 VAC) and 3RT20161AQ02 (380 VAC) / 3RT20161AV02 (400 VAC) cover higher control voltages commonly used in three-phase or higher-utility environments. Must-operate voltages scale accordingly (195.5 VAC, 323 VAC, 340 VAC).

Frequently asked questions

How soon can I get 3RT20161AF02 (3RT20161AF02)?

Availability moves with lots and channel inventory. Ships quickly when in stock; otherwise lead time follows distributor or factory lots. Phased shipments are common for production ramps.

What does this page list for “RoHS” on 3RT20161AF02?

The storefront table shows **RoHS**: ROHS3 Compliant. Treat it as a catalog snapshot—re-verify safety-critical ratings on the current manufacturer datasheet.

Second-source options near 3RT20161AF02?

Share the non-negotiable parameters (temperature, isolation, connector family, software hooks). We return only rows we can defend with catalog fields.

Datasheet and technical review for 3RT20161AF02?

Official PDFs beat search snippets. Open the linked document, cite the revision table, and send questions with the MPN line item.

What applications is 3RT20161AF02 suited for?

Fit depends on electrical, thermal, and mechanical constraints in your BOM—not on generic “industrial” labels. Describe the cabinet role and we map checks to on-page specs.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (8 parts) · columns 2+ sorted by Hub similarity to 3RT20161AF02

Technical resources

Lifecycle: ActiveRoHS: ROHS3 Compliant