Skip to main content
6EP13341LB00

Siemens 6EP13341LB00 SITOP 6EP1 DIN Rail Power Supply 24V 10A 240W

MPN6EP13341LB00Compare · similar
Active · In production

The Siemens 6EP13341LB00 is an actively produced SITOP 6EP1 series DIN rail power supply delivering 240W at 24V DC, 10A. Its auto-select dual-range AC input (93–132 VAC or 187–264 VAC) lets panel builders deploy the same unit on 120V North American mains or 230V international feeds without manual voltage selection or a step-down transformer. The unit measures 120.0mm × 70.0mm × 125.0mm and mounts on a TS35 rail, matc

PackagingBulk
Volume pricing1+ $181.77000
StockOut of Stock

Specifications

6EP13341LB00 Technical Specifications - Column 1
ParameterValue
Series6EP1
Efficiency89%
ApplicationsHazardous Locations, Industrial, ITE (Commercial)
CertificationsCB, CE, CSA, cUL, cULus, UL
AC Voltage Input93 ~ 132 VAC, 187 ~ 264 VAC
Minimum Order Quantity1
6EP13341LB00 Technical Specifications - Column 2
ParameterValue
Standards60950-1; UL 508
Rohs StatusROHS3 Compliant
Output Power240W
Output Current10A
Number Of Outputs1

Product details

24V DIN Rail Supply for SITOP 6EP1 Panel Builds

The 6EP13341LB00 drops into existing SITOP 6EP1 cabinet layouts without re-drilling or re-routing conductors.

On-page parameter snapshot

0mm × 70.0mm × 125.0mm

  • Mounting: TS35 DIN rail
  • IP rating: IP20
  • Certifications: CB, CE, CSA, cUL, cULus, UL (60950-1 / UL 508)
  • ROHS3 Compliant, REACH Unaffected, ECCN EAR99

Application fit for SITOP cabinet integrators

Tech-Savvy Sarah will notice this unit shares the single-output, adjustable-output architecture of the wider 6EP1 family. The universal-input design eliminates the dual-pole voltage selector switch found on some legacy SITOP bricks — fewer moving parts means fewer field callbacks. Input range 93–132 VAC handles North American branch circuits; 187–264 VAC covers single-phase international feeds without a step-down transformer.

When to pick the 6EP13341LB00 over the 6EP13343BA10

Both deliver 240W at 24V, 10A. The 6EP13341LB00 runs on single-phase mains only (93–132 or 187–264 VAC). The 6EP13343BA10 adds a 176–550 VAC two-phase input window — useful if your panel feed is 3-wire without neutral.

Procurement and replacement notes

One unit is available via RFQ confirmation. Volume pricing tiers kick in at 10, 25, and 50 units. If you're quoting a panel-build run of 10–100 units, factor in lead time verification — current evidence does not include quoted lead time for this MPN.

Design engineer's notes (limits and rails)

When siemens 6EP13341LB00 (AC/DC DIN RAIL SUPPLY 24V 240W); category path: Power Supplies - External/Internal (Off-Board) > Industrial, DIN Rail Power Supplies; confirmed specs: series: 6EP1; Package: Bulk; Product Status: Active is on the short list, reconcile every printed parameter (voltage tiers, current capability, package) with the schematic net names and protection devices you already committed.

Field notes for cabinet wiring checks

Field work should confirm grounding, shielding, and bus coordination with adjacent racks—especially when the raw record shows tight voltage or current margins.

Selection notes: wiring footprint and series

If procurement proposes a look-alike, require a side-by-side on the parameters that actually load the bus—channels, isolation, inrush, and protection class—not marketing series names alone.

What buyers are searching for

A PLC programmer or panel builder sourcing a SITOP 6EP1 240W 24V DIN rail supply for a control cabinet replacement or new build, evaluating input voltage compatibility (93–132 or 187–264 VAC), output current headroom (10A), and pin-compatible alternatives in the Siemens 6EP1 family.

Engineering notes

  • Auto-select input (93–132 / 187–264 VAC) removes the need for a manual voltage selector — fewer field misconfiguration risks on 120V North American mains.
  • 89% efficiency is 2 points lower than the 6EP13343BA10 (91%) — verify thermal budget in enclosed panels above 40°C ambient.
  • Adjustable output allows fine-tuning 24V bus under load; useful when long 24V trunk runs cause voltage sag at remote I/O.
  • IP20 chassis requires installation inside a cabinet — confirm enclosure rating requirements for the end application's hazardous-location rating.

When to choose this part

  • Pick this unit when the cabinet feed is single-phase 120V or 230V and DIN rail mounting is required — no step-down transformer needed.
  • If your panel uses 480V three-phase without neutral (176–550 VAC 2PH input), the 6EP13343BA10 is the only 240W active alternative in the 6EP1 family.
  • For 24V loads exceeding 10A continuous, the 6EP13341LD00 delivers 12.5A at 300W but is currently obsolete with zero stock — confirm lifecycle before specifying.
  • Verify terminal block accessibility and torque specs in the datasheet if replacing a unit with different terminal style (screw vs. spring clamp).

Limitations & things to verify

  • IP20 rating requires cabinet-level enclosure — not suitable for field mounting without additional environmental protection.
  • Single-output design; parallel operation for N+1 redundancy requires external diodes or Siemens SITOP redundancy modules (not included).
  • Current evidence does not include vibration ratings, MTBF figures, or warranty duration for this MPN — datasheet review recommended for harsh conveying or mobile equipment applications.
  • No on-board DC input (DC Voltage Input Min/Max fields are blank in evidence) — confirm DC operation capability if 24V battery backup feed is planned.

Frequently asked questions

Is the Siemens 6EP13341LB00 still in active production today?

Yes. The evidence_table lists product_status as Active for the 6EP13341LB00. This unit is not marked obsolete or end-of-life in the current dataset.

What is the closest pin-compatible alternative to the 6EP13341LB00 in this SITOP 6EP1 family?

The 6EP13343BA10 matches the output specs (24V, 10A, 240W) but is chassis-mount rather than DIN rail and adds a 176–550 VAC two-phase input range. The 6EP13341LD00 delivers 300W/12.5A but is obsolete (product_status: Obsolete) with zero stock. Neither is a drop-in pin-for-pin replacement — verify mounting and input compatibility in the datasheet before specifying.

What compliance documentation does Siemens provide for the 6EP13341LB00 (RoHS, REACH, UL, IEC)?

Evidence confirms ROHS3 Compliant, REACH Unaffected, and approval agencies CB, CE, CSA, cUL, cULus, and UL. Standards listed are 60950-1 and UL 508. ECCN is EAR99; HTS code is 8504.40.9530. Full Declarations of Conformity and test reports are available in the official Siemens datasheet.

What lead time does Siemens quote for the 6EP13341LB00 in panel-build quantities (10–100 units)?

Lead time is not present in current evidence for the 6EP13341LB00. Volume pricing tiers (10, 25, 50 units) appear in the dataset, indicating the MPN is available for multi-unit orders, but a quoted lead time for these quantities is not listed — request confirmation from distributor before committing to a panel-build schedule.

How does the 6EP13341LB00's electrical and mechanical life rating compare across the 6EP1 family?

Mechanical and electrical life ratings are not included in the current evidence_table for any 6EP1 MPN. MTBF, mean time between failures, and warranty duration fields are absent from the source documents. For lifecycle comparisons, consult the Siemens official product datasheet or contact a Siemens FAE directly.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (8 parts) · columns 2+ sorted by Hub similarity to 6EP13341LB00

Technical resources

Lifecycle: ActiveRoHS: ROHS3 Compliant