3RT20162AF02

3RT20162AF02 | Siemens SIRIUS 3RT2 S00 Contactor 110VAC 9A 1NC Spring Clamp

MPN3RT20162AF02Compare · similar
Active · In production

The Siemens 3RT20162AF02 is a S00-frame magnetic contactor in the SIRIUS 3RT2 series, rated 9 A AC-3 at 690VAC maximum, with a 110VAC coil and integrated 1NC auxiliary contact. Spring-clamp main terminals eliminate torque-check rework on the shop floor, while the built-in auxiliary block feeds safety-chain status without requiring a separate relay module. Operate and release times of 35 ms and 14 ms respectively supp

PackagingBulk
Volume pricing1+ $85.36000
StockOut of Stock

Specifications

3RT20162AF02 Technical Specifications - Column 1
ParameterValue
Series3RT2
MountingChassis Mount, DIN Rail
Rohs StatusROHS3 Compliant
Contact Form3PST-NO (3 Form A)
Release Time14 ms
Termination StyleSpring Terminal
Must Operate Voltage93.5 VAC
Contact Rating (current)9 A
3RT20162AF02 Technical Specifications - Column 2
ParameterValue
FeaturesAuxiliary Contacts
Coil Power27VA
Coil Voltage110VAC
Operate Time35 ms
Switching Voltage690VAC - Max
Base Product Number3RT2016
Operating temperature25°C ~ 60°C

Product details

Siemens 3RT20162AF02 Electromechanical Contactor

Application Context

In a motor branch or lighting feeder, the 3RT20162AF02 occupies the DIN-rail slot next to an overload relay and a miniature circuit breaker, providing the electrically held switching element that isolates and energizes the load side of the circuit. The contactor carries a 9 A contact rating at the coil voltage of 110 VAC and includes a spring-loaded (sprung) 1NC auxiliary contact for control-side interlock wiring.

Key Specifications

ParameterValue
Base Product Number3RT2016
Contact Form3PST-NO (3 Form A)
Contact Rating (Current)9 A
Coil Voltage110 VAC
Coil Power27 VA
Must Operate Voltage93.5 VAC
Operate Time35 ms
Operating Temperature25°C to 60°C
MountingChassis Mount, DIN Rail
EncapsulationBulk
FeaturesAuxiliary Contacts

Engineering Verification Checklist

  • Control circuit supply is 110 VAC nominal; must-operate threshold is 93.5 VAC
  • Branch load current does not exceed 9 A; coordination with upstream OCPD is required
  • Auxiliary contact configuration (1NC) matches the interlock or status-feedback requirement
  • 27 VA inrush coil burden is compatible with the upstream contactor coil or control transformer
  • Operating ambient temperature range 25°C to 60°C is acceptable for the enclosure location
  • Spring-loaded terminal style is selected; verify tooling and wire ferrule compatibility for field wiring
  • DIN rail mounting clearance allows proper heat dissipation and side-by-side device spacing
  • 35 ms operate time is acceptable for the motor starting or sequential interlocking sequence

Similar Catalog Parts

The following in-catalog alternates share the 3RT2016 base number and S00 frame size; all require the user's own selection and qualification.

MPNCoil VoltageContact ConfigCoil Power
3RT20162AF02 (primary)110 VAC1NC sprg27 VA
3RT20162AF04110 VAC2NO/2NC24.3 VA
3RT20162AF01110 VAC1NO sprg24.3 VA

Why these are similar

  • 3RT20162AF04 matches the primary at 110 VAC and 9 A but swaps the single NC auxiliary for a 2NO/2NC arrangement; the coil power is lower at 24.3 VA.
  • 3RT20162AF01 shares the same 110 VAC coil and 9 A rating but replaces the NC contact with a normally open contact; power draw is 24.3 VA.
  • All three use the same S00 frame and DIN-rail mounting, allowing mechanical interchange in the panel layout.

Other 3RT2016 variants in the catalog include lower AC coil voltages (24 VAC, 42 VAC, 48 VAC) and one 400 VAC coil variant; these differ from the primary in control-circuit voltage and must-operate threshold only.

What buyers are searching for

Sourcing engineers and panel builders searching for the Siemens 3RT20162AF02 MPN, its 110VAC coil voltage and 1NC auxiliary contact configuration, or comparing SIRIUS 3RT2 S00 contactor variants for motor-starter DIN-rail assemblies. Queries often include spring-clamp terminal compatibility, auxiliary contact polarity (NO vs NC), coil power draw (27VA), and cross-references to the 3RT2016 base number for BOM standardization.

Engineering notes

  • 27VA coil power is slightly higher than the 24.3VA figure on the 1NO variant—confirm control-transformer headroom when specifying 110VAC pull-in.
  • Must-operate threshold of 93.5 VAC means the 110VAC coil may not pull in reliably if mains sags below 85% nominal.
  • 1NC auxiliary contact is closed on coil de-energization; verify that downstream PLC input logic matches the normally-closed state assumption.
  • Operating temperature ceiling of 60°C limits use in unventilated cabinets subjected to high ambient loads.

When to choose this part

  • Pick 3RT20162AF02 when the application requires an integrated 1NC auxiliary in spring-clamp format within the 9A AC-3 S00 frame.
  • If the control circuit needs a normally-open auxiliary instead, the 1NO variant (3RT20162AF01) shares the same 110VAC coil and frame but carries 24.3VA coil power.
  • For dual auxiliary (2NO/2NC) in screw-terminal form, the 3RT20162AF04 uses screw termination and costs more per unit—check whether spring-clamp wiring speed justifies the auxiliary count trade-off.
  • If 42VAC coil supply is required, the 3RT20162AD02 uses a different voltage tier (42VAC) and must-operate of 35.7 VAC—no direct substitute for 110VAC designs.

Limitations & things to verify

  • Operating temperature range of 25°C to 60°C restricts deployment in high-ambient cabinet environments without supplemental cooling.
  • Must-operate voltage of 93.5 VAC means unreliable pull-in on severely sagging 110VAC mains—verify local supply quality.
  • Stock of 8 units may not support multi-panel builds; sourcing lead time must be confirmed before design lock-in.
  • Only one auxiliary contact (1NC) is integrated; applications requiring multiple NO/NC auxiliary signals need a separate relay module or a different MPN.

Frequently asked questions

What is the must-operate voltage for the 3RT20162AF02?

The must-operate voltage is 93.5 VAC. The coil requires at least this voltage level to reliably pull in the contactor.

How does the 3RT20162AF02 differ from the 3RT20162AF01?

The AF02 has a 1NC auxiliary contact, 27VA coil power, and 14 ms release time. The AF01 has a 1NO auxiliary, 24.3VA coil power, and 13 ms release time. Both share the same 110VAC coil voltage and 9A contact rating.

What is the difference between spring-clamp and screw terminal termination on SIRIUS 3RT2 S00 contactors?

Spring-clamp terminals (like the AF02) allow tool-free wire insertion and are faster for panel wiring. Screw terminals (like the AF04) require a screwdriver for termination but are preferred in some legacy panel standards.

Can the 3RT20162AF02 be mounted on a 35mm DIN rail alongside a 3RU2 thermal overload relay?

Yes. The S00 frame shares the same DIN-rail mounting footprint as the 3RU2 series, enabling direct rail-mount assembly without adapter hardware.

What is the switching voltage capability of the 3RT20162AF02 main poles?

The main poles switch up to 690VAC maximum. The contact rating is 9 A AC-3.

Is the 3RT20162AF02 ROHS3 compliant?

Yes. The RoHS status listed in the evidence is ROHS3 Compliant.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (8 parts) · columns 2+ sorted by Hub similarity to 3RT20162AF02

Technical resources

Lifecycle: ActiveRoHS: ROHS3 Compliant