16 ns reverse recovery time at 5 A forward current. 2 V forward drop at 5 A is the conduction-loss side of the trade-off.
The tab is electrically common with the cathode — account for isolation when bolting to a grounded heatsink. 40 µA reverse leakage at 500 V is the high-temperature design point; derate the junction temperature below the 150 °C maximum for long-life PFC stages.
Active lifecycle status — no last-time-buy or phase-out notice on this part.