Skip to main content
NXP Semiconductors BTA212-600F,127 — Discrete Semiconductors

BTA212-600F,127 WeEn Standard Triac, 600V 12A TO-220-3

MPNBTA212-600F,127
End of Life

WeEn BTA212-600F,127 standard triac, single configuration, 600 V off-state, 12 A RMS on-state, 25 mA gate trigger, 1.5 V gate trigger, through-hole TO-220-3 package.

$0.41Ref. price · indicative, final on quote
PackagingTO-220-3
Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

BTA212-600F,127 specifications
ParameterValue
Triac typeStandard
MountingThrough Hole
Voltage - off state600 V
Voltage - gate trigger (Vgt)1.5 V
Current - hold (Ih)30 mA
Current - gate trigger (Igt)25 mA
Current - on state (It (RMS))12 A
Current - non rep. surge 50, 60Hz95A, 105A
Operating temperature125°C (TJ)
PackageBulk
ConfigurationSingle
CaseTO-220-3

Product details

Gate drive and trigger levels

With a 25 mA maximum gate trigger current and 1.5 V maximum gate trigger voltage, this triac is compatible with standard logic-level drivers — an MCU GPIO through a series resistor and a small transistor, or a dedicated triac driver like a MOC30xx. The 30 mA hold current means the load must draw at least that much to keep the triac latched once triggered; below that, the device will commutate off at zero-cross. That is typical for a standard triac and fine for most AC loads, but if you are switching a very light load (a few watts), verify the load current exceeds the hold current over the full cycle.

Frequently asked questions

Is BTA212-600F,127 suitable for 240V AC switching?

Yes. The 600 V off-state voltage rating provides over 75% margin above the 340 V peak of a 240 VAC sine wave, which covers normal switching transients and line surges.

What is the exact gate trigger voltage of BTA212-600F,127?

The maximum gate trigger voltage is 1.5 V. The maximum gate trigger current is 25 mA.

What is the difference between BTA212-600F,127 and a standard triac?

This part IS a standard triac — it is not a snubberless (alternistor) type. Standard triacs require a snubber RC network across the MT1-MT2 terminals when switching inductive loads to prevent false triggering from dV/dt. A snubberless triac handles higher dV/dt without the external network.

Where can I buy BTA212-600F,127?

This part is sourced to order against an RFQ through independent distribution. Current pricing and stock levels are confirmed at quote time — submit an RFQ for a firm quote.

What is the gate trigger current of BTA212-600F?

The maximum gate trigger current is 25 mA.