Skip to main content
0603SFV075F-32-2

Littelfuse 0603SFV075F/32-2 Fuse, 800mA, 32V, Fast Blow

MPN0603SFV075F/32-2
Obsolete

Littelfuse Inc. SFV series, Board Mount Surface Mount Fuse, 0603 (1608 Metric), 800 mA, 32 V DC, Fast Blow, 50 A Breaking Capacity, UL Approved.

$3.1600Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

0603SFV075F/32-2 specifications
ParameterValue
SeriesSFV
Fuse typeBoard Mount (Cartridge Style Excluded)
MountingSurface Mount
Voltage rating - DC32 V
Breaking capacity @ rated voltage50A
Current rating800 mA
Response timeFast Blow
Operating temperature-55°C~125°C
Size (Dimension)0.063\" L x 0.031\" W x 0.014\" H (1.60mm x 0.80mm x 0.35mm)
Approval agencyUL
PackageTape & Reel (TR); Cut Tape (CT)
Melting i2t0.0191
Case0603 (1608 Metric)
DC cold resistance0.45 Ohms

Product details

800 mA fast-blow in a 0603 footprint

The 0603SFV075F/32-2: Rated 800 mA continuous at 32 V DC with a 50 A breaking capacity at rated voltage — the fuse clears a short-circuit fault up to 50 A without rupturing the 0603 ceramic body. The fast-blow response time means it opens quickly on moderate overcurrents, suiting it for protecting sensitive IC power rails where a slow-blow would let the silicon cook before clearing. Melting I²t is 0.0191 — this is the energy needed to melt the fuse element. For inrush-limited designs, the I²t of the fuse must exceed the I²t of the charging pulse; a 0.0191 value is typical for protecting a small DC-DC input or a peripheral supply rail in portable equipment. DC cold resistance is 0.45 Ohms — at 800 mA the voltage drop across the fuse is about 360 mV, which matters for low-voltage rails where every millivolt of headroom counts.

0603 surface-mount — board-fit and storage

Housed in a standard 0603 (1608 metric) ceramic package, 1.60 mm x 0.80 mm x 0.35 mm. The surface-mount footprint matches the common 0603 resistor/capacitor land pattern — no special pad geometry needed. Operating temperature range is -55°C to 125°C, covering automotive under-hood and industrial ambient extremes. The UL approval certifies the fuse to UL 248-14 standard for supplementary overcurrent protection.

Frequently asked questions

What is the breaking capacity of 0603SFV075F/32-2?

50 A at the rated 32 V DC. This means the fuse can safely interrupt a fault current up to 50 A without bursting or arcing — adequate for secondary-side protection in most low-voltage DC circuits.