Skip to main content
Littelfuse Inc. 0603SFS350F/32-2 — Circuit Protection

0603SFS350F/32-2 Littelfuse SFS 3.5A 32V Slow-Blow Fuse

MPN0603SFS350F/32-2
Obsolete

Littelfuse SFS series board-mount slow-blow fuse, 0603 (1608 metric) surface-mount package, 3.5 A, 32 V DC, 50 A breaking capacity, UL approved.

$0.8300Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

0603SFS350F/32-2 specifications
ParameterValue
SeriesSFS
Fuse typeBoard Mount (Cartridge Style Excluded)
MountingSurface Mount
Voltage rating - DC32 V
Breaking capacity @ rated voltage50A
Current rating3.5 A
Response timeSlow Blow
Operating temperature-55°C ~ 125°C
Size (Dimension)0.063\" L x 0.031\" W x 0.031\" H (1.60mm x 0.80mm x 0.80mm)
Approval agencyUL
PackageTape & Reel (TR) Cut Tape (CT)
Melting i2t1.2
Case0603 (1608 Metric)
DC cold resistance0.021 Ohms

Product details

What 3.5 A at 32 V DC means for your protection scheme

The 0603SFS350F/32-2 is a Littelfuse SFS series slow-blow surface-mount fuse rated 3.5 A continuous at 32 V DC. The slow-blow characteristic means it tolerates brief inrush currents — motor start-up, capacitor charging, hot-swap events — without opening, while still clearing sustained overloads. The 50 A interrupting rating at 32 V DC confirms it can safely break a fault current up to that level without arc re-strike or casing rupture. The 0603 footprint (1.60 mm x 0.80 mm x 0.80 mm) fits high-density PCB layouts where board space is at a premium. Cold resistance of 0.021 Ohms keeps the voltage drop under 75 mV at rated current, minimizing power loss in the protection path.

Obsolete — sourcing reality for the BOM line

Each lot is verified for date-code consistency, marking integrity, and packaging authenticity before shipment — the laser etch on the body and reel labels are checked against known Littelfuse plant formatting.

UL approval provides regulatory acceptance for equipment sold into North American markets. The melting I²t of 1.2 is the coordination parameter for fuse-to-circuit sizing — downstream components must withstand the energy let-through before the fuse clears.

Frequently asked questions

What is the breaking capacity of the 0603SFS350F/32-2?

50 A at the rated 32 V DC. This is the maximum fault current the fuse can safely interrupt without arcing or casing failure.