F1206A0R20FWTR

KYOCERA AVX

KYOCERA AVX Accu-Guard® series, F1206A0R20FWTR, 200 mA rated current, 32 V DC, fast-blow, surface-mount 1206 (3216 metric) fuse, 50 A breaking capacity at rated voltage.

KYOCERA AVX F1206A0R20FWTR — Circuit Protection
Download datasheet (PDF)
[QUOTE] Factory Allocation · Direct Sourcing
Target price / quote

Volume pricing available from 1,000+ pcs per order.

MOQ 1 · Tape & Reel (TR) · RoHS · EIA-481 · DAP/DDP · T/T

RFQ — this part

Submit without leaving this page. Same pipeline as the BOM / RFQ form.

First response typically within one business day; complex BOMs may take longer.

Technical specifications

F1206A0R20FWTR specifications
Parameter / AttributeSpecification / Value
SeriesAccu-Guard®
Fuse typeBoard Mount (Cartridge Style Excluded)
MountingSurface Mount
Voltage rating - DC32 V
Breaking capacity @ rated voltage50A
Current rating200 mA
Response timeFast Blow
Operating temperature-55°C~125°C
Size (Dimension)0.122\" L x 0.063\" W x 0.047\" H (3.10mm x 1.60mm x 1.20mm)
Approval agencycUL, UL
PackageTape & Reel (TR)
Melting i2t2E-05
Case1206 (3216 Metric)
DC cold resistance0.95 Ohms

Technical details

200 mA fast-blow fuse for 32 V DC rails

The F1206A0R20FWTR is a 200 mA fast-blow fuse from KYOCERA AVX's Accu-Guard® series, rated for 32 V DC. It comes in a 1206 (3216 metric) surface-mount package, making it a direct fit for board-level overcurrent protection on low-voltage DC rails — think 24 V industrial sensor supplies, 12 V automotive accessory buses, or 5 V logic power inputs where a short could otherwise toast a regulator or a connector. The fast-blow response means it opens quickly on a hard short, but it will also trip on repetitive inrush pulses that exceed the melting I²t of 2E-05 A²s. If your load has a capacitive input filter that draws a charging spike at power-up, check the I²t budget against the inrush energy — this fuse is not designed to ride through large start-up surges.

Breaking capacity and temperature range

Rated breaking capacity is 50 A at 32 V DC — that is the maximum fault current the fuse can safely interrupt without rupturing or sustaining an arc. In a typical 24 V industrial control cabinet where the available short-circuit current from a 10 A PSU is well under 50 A, this fuse provides adequate fault clearing. If your rail can deliver more than 50 A into a dead short, you need a higher-interrupting-rated fuse or a current-limiting breaker upstream. At the hot end, the fuse's DC resistance of 0.95 Ohms (cold) will increase with temperature, so the voltage drop across the fuse at 200 mA is about 190 mV at 25°C — factor that into your rail budget if you are running near the minimum input voltage of a downstream regulator.