300 mA fixed-limit high-side switch — BOM-fit realities
The fixed current-limiting fault protection means the trip point is not adjustable — if your load peak exceeds 300 mA, this part will clamp it, not pass it.
1 Ohm Rds(on) — voltage drop budget for a 300 mA rail
At 300 mA the 1 Ohm max on-resistance drops 300 mV across the switch.
6-DSBGA — design-in checklist for this footprint
The 6-DSBGA package requires X-ray inspection for solder-joint verification.
Active production — straightforward sourcing
No official successor has been issued because no replacement is needed.