Skip to main content
Omron E3T-FT12 — Interface & Transceivers

Omron E3T-FT12 Through-Beam Sensor, 500mm NPN Dark-ON

MPNE3T-FT12
Active

Omron E3T series through-beam photoelectric sensor, E3T-FT12, NPN open collector Dark-ON output, 500 mm sensing distance, 12 V supply, red 650 nm LED, IP67, cable connection, 1 ms response, -25°C to 55°C.

$144.36Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

E3T-FT12 Technical Specifications
ParameterValue
SeriesE3T
Connection_methodCable
Operating temperature high-25°C to 55°C
Ip_ratingIP67
Output_typeNPN - Open Collector/Dark-ON
Light_sourceRed (650nm)
Package_typeBulk
Sensing_typeThrough-Beam
Response_time_ms1
Supply_voltage_v12
Sensing_distance_max_mm19.685

Product details

Through-beam at 500 mm — what it means on the line

The Omron E3T-FT12 is a through-beam photoelectric sensor with a 500 mm sensing distance, NPN open-collector Dark-ON output, and a red 650 nm LED source. It is designed for discrete part-present detection, counting, and break-beam alignment on conveyors, packaging lines, and automated assembly stations where the emitter and receiver mount opposite each other. The IP67 rating means it handles washdown and dusty environments without an additional enclosure.

Response time and supply — fit for standard industrial I/O

The 1 ms response time suits discrete part-present and counting applications. It is not suited for high-speed registration or sub-millisecond edge capture.

Frequently asked questions

What is the difference between E3T-FT12 and E3T-FT11?

The E3T-FT12 has a Dark-ON output (NPN conducts when beam is blocked), while the E3T-FT11 has a Light-ON output (NPN conducts when beam is clear). Both share the same 500 mm sensing distance, IP67 rating, 1 ms response, and cable connection. Swapping them changes the logic of the downstream PLC input.

Can I use a PNP output sensor instead of the E3T-FT12?

Yes, the E3T-FT13 is the PNP Light-ON counterpart in the same E3T series. It has the same sensing distance, response time, and IP67 rating, but outputs a positive voltage instead of sinking to ground. Verify your PLC input module accepts PNP sourcing before substituting.