Industrial temperature grade — deployment scope
Rated -40°C to 85°C (TA), this part is specified for environments where the ambient temperature swings beyond commercial limits. That includes outdoor base stations, engine-bay-adjacent electronics, and unheated enclosures. The mobile LPSDR technology also draws lower standby current than standard SDRAM at the same temperature, which helps in thermally constrained enclosures.
Lifecycle and sourcing
Listed as Active with ROHS3 compliance. No EOL notice or successor is on record. This part is sourced through independent distribution and quoted to order against an RFQ.