This BTS410F2E3062ABUMA1 carries an Obsolete lifecycle status, meaning Infineon has ended production and no further factory orders are accepted.
Rds(on) rises with junction temperature — the -40°C to 150°C operating range means the actual on-resistance at 125°C junction can be roughly 1.5× the 25°C typical value, so budget thermal headroom accordingly.
Fault protection set — over-temperature, over-voltage, current limiting, open-load detect
The Auto Restart feature means the switch re-enables after a thermal fault once the junction cools, which is useful for intermittent overloads but requires the downstream load to tolerate cycling.
Package and mounting — TO-263-5 D²Pak
Standard reflow profiles for lead-free solder apply.