TVS diode for 200V rail protection
The SMBJ200A-13-F: Its 224V minimum breakdown voltage ensures the device stays off during normal operation, while the 324V maximum clamping voltage at 1.9A peak pulse current (10/1000µs waveform) limits the overvoltage seen by the protected load.
Pulse power and thermal budget
The 1.9A peak pulse current at the clamping voltage means the device absorbs the surge energy without exceeding its junction temperature limit of 150°C.
DO-214AA SMB surface-mount footprint
Housed in the DO-214AA (SMB) package, the SMBJ200A-13-F uses a standard surface-mount footprint compatible with reflow soldering.