Skip to main content
Analog Devices MAX706TESA-T — Memory (DRAM / SRAM / Flash / EEPROM)

MAX706TESA-T Power Supply Monitor, Active Low Reset

MPNMAX706TESA-T
End of Life

Maxim Integrated MAX706TESA-T, Power Supply Monitor, Active Low Reset, Push-Pull Output, 140ms Minimum Reset Timeout, 3.08V Threshold, 8-SOIC, -40°C to 85°C.

$4.35Ref. price · indicative, final on quote
Packaging8-SOIC (0.154", 3.90mm Width)
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

MAX706TESA-T Technical Specifications
ParameterValue
TypePower Supply Monitor
Mounting typeSurface Mount
Voltage - threshold3.08V
Number of voltages monitored1
Operating temperature-40°C ~ 85°C (TA)
ResetActive Low
OutputPush-Pull, Totem Pole
PackageBulk
Reset timeout140ms Minimum
Case8-SOIC (0.154\", 3.90mm Width)

Product details

Supervisor for a single 3.3V rail

The Maxim Integrated MAX706TESA-T is a power-supply monitor IC that asserts a reset signal to a processor or logic when the monitored voltage drops below a 3.08 V threshold. The reset output is active-low, push-pull (totem pole), and holds for a minimum of 140 ms after the supply returns above threshold — long enough for most MCUs and SoCs to complete a clean power-on reset sequence. It monitors a single voltage rail and comes in an 8-SOIC surface-mount package rated for -40°C to 85°C ambient.

140 ms reset timeout — what it buys you

The reset timeout is a minimum of 140 ms. The output holds low after the supply recovers above 3.08 V.

Active production — no LTB clock ticking

The product status is active with no end-of-life notification. It can be designed into a new BOM without scheduling a last-time buy.

Sourcing and fit for the BOM

This is a single-rail supervisor in an 8-SOIC footprint. The push-pull output eliminates the need for an external pull-up resistor.

Frequently asked questions

What is the reset timeout of MAX706TESA-T?

The reset timeout is a minimum of 140 ms. The reset output stays low for at least that long after the supply voltage rises above the 3.08 V threshold.

Where can I buy MAX706TESA-T?

This part is available to order through independent distribution. Submit an RFQ for current pricing and delivery confirmation — availability is confirmed at quote time.

What voltage threshold does MAX706TESA-T monitor?

The monitored threshold is 3.08 V. When the supply rail falls below that level, the reset output asserts low.

Is MAX706TESA-T active low or active high?

The reset output is active low, with a push-pull (totem pole) stage.

What is the closest pin-compatible alternative to MAX706TESA-T?

The MAX706TESA-T follows the industry-standard 706 supervisor pinout. Pin-compatible alternatives include the DS1813 (verify threshold and timeout) and other 706-family supervisors from various vendors. For a direct Maxim replacement with RoHS compliance, consider the MAX706TESA+.