MAX6665ASA60 Fan Controller IC – Analog Devices, 60°C Trip

MPN MAX6665ASA60
End of Life Spot Stock · 24-48h Dispatch 100% Original Sealed

Analog Devices MAX6665ASA60 fan controller, 8-SOIC exposed pad, switching temperature 60°C, ±3°C accuracy, active-high/active-low open-drain or push-pull outputs, 65 µA supply current, 2.7 V to 5.5 V supply range, -40°C to 125°C operating range.

In Stock: 8,552 pcs
MOQ: 1 pcs
Logistics: DHL / FedEx DAP (Global Express · 3-7d) Russia & CIS DDP (Door-to-Door Cleared)
Dispatch: Shenzhen / HK
Unit Price (USD)
$2.27 / pc
Direct Purchase Ready
Volume Pricing Breaks Confirmed upon quotation
1+ pcs
$2.27
10+ pcs
$2.04
30+ pcs
$1.86
100+ pcs
$1.68
500+ pcs
$1.57
1,000+ pcs
$1.48
Working on a production BOM or have a target unit price? Submit Target Price
Buy Now

$2.27 / ea

8,552 in stock — maximum per order · 3–4 days lead time

$2.04 / ea from 10 pcs

Upload Full BOM List
[SPEC] Essential Parameters Snapshot Full Specifications (14)
Package / Case 8-SOIC (0.154", 3.90mm Width) Exposed Pad
Supply Voltage 2.7 V ~ 5.5 V

Full Technical Specifications

14 Parameters
MAX6665ASA60 specifications
Parameter / AttributeSpecification / Value
Output typeOpen Drain, Push-Pull
MountingSurface Mount
Supply voltage2.7 V ~ 5.5 V
Current - supply65µA
Output current250mA
Operating temperature-40°C ~ 125°C
OutputActive High, Active Low
PackageBulk
Accuracy±3°C
Case8-SOIC (0.154\", 3.90mm Width) Exposed Pad
Output functionFanOn, /FanOut, /OverTemp, /Warn
Selectable hysteresisYes
Switching temperature60°C
Trip temperature thresholdHot
[DESK] Shenzhen Spot Allocation · 2h Response

Need Immediate Spot Stock or Shortage Allocation for MAX6665ASA60?

Factory lead times blocking production? We lock verified brand-new original stock in Shenzhen within 2 hours.

Quote SLA 2 Hours
[01] Emergency Shortage 24-48h Shenzhen Dispatch

Direct access to Shenzhen floor inventory, franchised allocation buffers, and factory bonded stock to resolve line-down shutdowns.

[02] Industrial Packaging Tape & Reel / Tray / Tube

Standard factory-sealed packaging compliant with EIA-481 standards for automated high-speed SMT pick-and-place lines.

[03] WhatsApp QC Proof 45x Microscope QC Photos

High-resolution photos of original reel labels, 2D DataMatrix, and pin coplanarity sent via WhatsApp/Telegram before you release wire payment.

● USD Wire Transfer (SWIFT T/T) · DAP Express / DDP Delivery

Technical Details & Description

60°C trip point with ±3°C accuracy

The MAX6665ASA60 is a temperature-switch fan controller from Analog Devices that asserts its outputs when the die temperature crosses 60°C. The ±3°C accuracy sets the guard band. Four output functions — FanOn, /FanOut, /OverTemp, /Warn — give the designer separate signals to start the fan, indicate an overtemperature fault, and provide a pre-warning. The outputs are configurable as open-drain or push-pull, active-high or active-low, which simplifies interfacing to both legacy and modern logic families. Selectable hysteresis prevents output chatter around the trip point, a practical concern when the thermal mass of the heatsink or enclosure is small relative to the power dissipation.

Supply range and drive capability

Supply current is 65 µA typical, which keeps the self-heating contribution negligible in the temperature measurement. The output can sink or source up to 250 mA.

Active lifecycle in 8-SOIC exposed pad

The SOIC exposed-pad package provides a low thermal resistance path from the die to the PCB copper plane, which is essential for accurate die-temperature sensing. RoHS non-compliant — if your assembly requires RoHS conformance, confirm the exemption or seek an alternative. The part is, so plan for tape-and-reel if your pick-and-place line requires it.

Frequently asked questions

What does the ±3°C accuracy mean for my thermal design?

The Switching Temperature of 60°C has a total accuracy of ±3°C, so the actual trip point can be as low as 57°C or as high as 63°C. Selectable hysteresis lets you add a deadband to prevent oscillation.

MAX6665ASA60
Verified Allocation
Quote