Analog Devices MAX22246CAWA+ — Digital Isolators

MAX22246CAWA+ Digital Isolator, 200 Mbps, 5000 Vrms, 2-Ch

MPNMAX22246CAWA+
End of Life

Maxim Integrated MAX22246CAWA+, reinforced 2-channel digital isolator, capacitive coupling, 200 Mbps data rate, 5000 Vrms isolation, 1.71 V to 5.5 V supply, -40°C to 125°C, 8-SOIC wide-body package, unidirectional channels.

$4.04Ref. price · indicative, final on quote
Packaging8-SOIC (0.295", 7.50mm Width)
RoHSROHS3 Compliant
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

MAX22246CAWA+ specifications
ParameterValue
TypeCAN, RS232, RS422, RS485
Channel typeUnidirectional
MountingSurface Mount
Voltage1.71V ~ 5.5V
Voltage - isolation5000Vrms
Isolated powerNo
Operating temperature-40°C ~ 125°C
Pulse width distortion2ns
PackageTube
Data rate200Mbps
TechnologyCapacitive Coupling
Case8-SOIC (0.295\", 7.50mm Width)
Channels2
Inputs - side 1/Side 21/1
Rise (Fall time)0.8ns, 1ns (Max)
Propagation delay tpLH (tpHL)9.5ns, 9.9ns
Common mode transient immunity50kV/µs (Typ)

Product details

Reinforced 2-channel isolator for high-speed industrial buses

It supports a 200 Mbps data rate with 5000 Vrms isolation, making it suited for isolating CAN, RS-232, RS-422, and RS-485 interfaces in industrial automation, motor drives, and medical equipment. The wide supply range of 1.71 V to 5.5 V allows direct interface with both 1.8 V and 5 V logic domains without a separate level shifter.

Propagation delay and pulse-width distortion

Maximum propagation delay is 9.5 ns (tpLH) and 9.9 ns (tpHL), with pulse-width distortion limited to 2 ns. These timing specs keep the signal edge integrity tight enough for 200 Mbps NRZ data without accumulating jitter across the isolation barrier. Rise and fall times are 0.8 ns and 1 ns typical, so the output edges are clean enough to drive a standard CMOS or TTL input without extra buffering.

Common-mode transient immunity for noisy environments

Minimum common-mode transient immunity is 50 kV/µs (typical). That figure matters when the isolator bridges a motor-drive power stage or a switched-mode supply where fast voltage transients across the barrier could otherwise corrupt the data stream.

Housed in a wide-body 8-SOIC (0.295", 7.50 mm width) package, surface-mount. The channels are unidirectional with a 1/1 input-to-output split, so two signal lines can cross the barrier in opposite directions.

For production BOMs requiring reinforced isolation at 200 Mbps, this part is specified into new designs without LTB risk.

Frequently asked questions

Is MAX22246CAWA+ obsolete or has an EOL notice?

It remains suitable for new designs.

What is the data rate of MAX22246CAWA+?

The MAX22246CAWA+ supports a data rate of 200 Mbps.