VO615A-3X009T

Vishay

Vishay VO615A-3X009T single-channel DC-input optocoupler, transistor output, 5000Vrms isolation, 100-200% CTR at 10mA, 70V output max, 50mA output current, 4-SMD Gull Wing package, -55°C to 110°C.

Vishay VO615A-3X009T
Download datasheet (PDF)
[IN STOCK] In Stock: 360 pcs
$0.36/ pc

Volume pricing

Buy Now

Subtotal:$1.80

MOQ 5 · Tape & Reel (TR); Cut Tape (CT) · RoHS · EIA-481 · DAP/DDP · T/T

Technical specifications

VO615A-3X009T specifications
Parameter / AttributeSpecification / Value
Input typeDC
Output typeTransistor
MountingSurface Mount
Voltage - isolation5000Vrms
Voltage - output70V
Voltage - forward (Vf)1.43V
Current - output (Channel)50mA
Current transfer ratio200% @ 10mA
Current - DC forward (If)60 mA
Operating temperature-55°C ~ 110°C
PackageTape & Reel (TR); Cut Tape (CT)
Case4-SMD, Gull Wing
Channels1
Vce saturation300mV
Rise (Fall time)3µs, 4.7µs
Turn on (Turn off time)6µs, 5µs

Technical details

5000Vrms isolation in a 4-SMD gull-wing package

Packaged in a 4-SMD gull-wing format, it provides reinforced isolation for industrial and power-conversion applications where safety spacing and transient immunity matter.

The VO615A-3X009T is specified with a current transfer ratio (CTR) of 100% minimum and 200% maximum, both measured at 10 mA forward current. This bin (the '3' in the suffix) gives the designer a predictable gain window: at 10 mA LED drive, the output transistor will sink between 10 mA and 20 mA with the output collector voltage held within the 70V maximum rating. The 300 mV Vce saturation at that current is tight enough to drive logic-level inputs without an extra pull-up resistor.

Switching speed and the 70V output ceiling

Rise and fall times are 3 µs and 4.7 µs typical, with turn-on and turn-off times of 6 µs and 5 µs respectively. This limits the part to DC-level sensing, slow status feedback, or relay-driver applications rather than high-speed data isolation. The 50 mA continuous output per channel and 70V collector-emitter rating cover most 24V and 48V industrial logic rails with margin.

The 60 mA absolute-maximum forward current gives headroom for pulse-drive schemes that boost CTR at cold temperatures.

DC input only — not for AC line sensing

The input type is listed as DC, meaning the internal LED is a single die without an anti-parallel pair. For AC mains detection or zero-crossing circuits, you would need a back-to-back LED optocoupler or an external bridge rectifier. The 1.43V typical forward voltage at 10 mA is standard for infrared LEDs in this class.

VO615A-3X009T
[ALLOC] verified