The 1.5SMC220CAHM3/H: The 185 V reverse standoff voltage and 328 V clamping ceiling mean it protects 185 V nominal rails from transients up to 4.6 A peak pulse current without exceeding the clamping limit.
Clamping voltage and pulse current — what they mean for the rail
For a 185 V nominal bus, the 143 V margin between standoff and clamp gives headroom for load-dump and inductive kickback without the TVS conducting during normal ripple. The 209 V minimum breakdown voltage ensures the device starts clamping before the rail exceeds the downstream component's absolute maximum rating — a key parameter for selecting the TVS against the protected IC's V(BR) spec.
Listed as Active by Vishay.