Last-time-buy status and what it means for your BOM
The 1.5KE91A-E3/51: Vishay has placed the 1.5KE91A-/51 on Last Buy status — the manufacturer is no longer accepting unlimited orders, and the remaining production window is finite.
What the 1.5 kW rating means in a real circuit
At the 12 A peak pulse current the device clamps at 125 V maximum, so a 77.8 V nominal rail sees the overvoltage limited to 125 V before the TVS absorbs the energy.
Through-hole mounting in a DO-201AA (DO-27) axial-lead package — the 1.5KE series footprint is a standard two-hole pattern on 0.300-inch centres, compatible with wave-solder assembly.