TransZorb TVS for 7.78 V rails
The 1.5KE9.1A-E3/54: Its 8.65 V minimum breakdown ensures the device stays off during normal operation while the 13.4 V clamp at 112 A (10/1000 µs) limits the voltage spike the downstream circuitry sees.
Pulse rating and thermal margin
The -55°C to 175°C operating range means the derating curve starts well above typical ambient — at 25°C you get the full 1500 W, but at 125°C the power drops to roughly 75% of the headline figure.