1.5KE82HE3/73 Vishay TVS, 1500W, 66.4V Standoff, AEC-Q101

MPN1.5KE82HE3/73
Obsolete

Vishay General Semiconductor - Diodes Division, TransZorb® TVS, Zener, 1.5KE82HE3/73, 1500W peak pulse, 66.4V reverse standoff, 118V clamp, DO-201AA axial, AEC-Q101.

Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

1.5KE82HE3/73 specifications
ParameterValue
TypeZener
SeriesAutomotive, AEC-Q101, TransZorb®
MountingThrough Hole
Voltage - breakdown73.8V
Voltage - clamping (Max) @ ipp118V
Voltage - reverse standoff66.4V
Current - peak pulse (10/1000μs)12.7A
Power - peak pulse1500W (1.5kW)
Power line protectionNo
Operating temperature-55°C~175°C(TJ)
PackageTape & Box (TB)
ApplicationsAutomotive
CaseDO-201AA, DO-27, Axial
Unidirectional channels1

Product details

Transient suppressor with AEC-Q101 pedigree — now obsolete

The 1.5KE82HE3/73 is a 1500 W unidirectional TVS Zener from Vishay's TransZorb® series, qualified to AEC-Q101 for automotive use.

Clamping and breakdown window

Breakdown voltage is guaranteed between 73.8 V and the clamp ceiling — the 118 V clamp at 12.7 A Ipp means a 48 V bus sees the TVS stay off below 66.4 V, then snap in hard during a surge. The 1500 W peak pulse rating (10/1000 µs) is the energy-handling floor for load-dump or inductive kickback events in an engine-bay environment. No power-line protection (the device is unidirectional, single-channel) — it protects one rail per package, typical for point-of-load clamping on sensor or actuator power feeds.

Frequently asked questions

What is the closest alternative to 1.5KE82HE3/73 in the same family?

A functionally similar TVS with the same 66.4 V standoff and 1500 W rating would require a new qualification — the AEC-Q101 pedigree is specific to this TransZorb series.

What compliance documentation does Vishay provide for 1.5KE82HE3/73?

The part carries AEC-Q101 automotive qualification, which implies PPAP-level documentation and reliability test data per the standard. RoHS and REACH compliance status should be confirmed on the specific date-code lot at RFQ — Vishay typically provides certificates for the TransZorb series.