Breakdown and clamping — the parametric guardrails for circuit design
The 1.5KE75CAHE3_A/D: Minimum breakdown voltage is 71.3 V, ensuring the device begins conducting before the protected rail exceeds that threshold; the 64.1 V standoff rating means the TVS draws negligible leakage at normal operating voltage up to that level. Clamping at 104 V maximum limits the voltage seen by downstream components during a surge — a critical number for selecting downstream capacitor voltage ratings and semiconductor BVdss margins. The single bidirectional channel protects a single signal or power pair against both positive and negative transients, simplifying layout and reducing component count compared to two unidirectional devices back-to-back.
Active production — no obsolescence risk for BOM continuity
Sourced through authorized and independent distribution channels; pricing and lead time are confirmed at RFQ against the BOM quantity.