Key voltage and power ratings for BOM fit
The 1.5KE200AHE3_A/D: The reverse standoff voltage (171 V) defines the maximum DC or peak operating voltage the device can withstand without conducting — above that, the TVS enters breakdown. Operating temperature range spans -55°C to +175°C, covering the full automotive underhood ambient and the self-heating margin during a surge.
Supplied in a DO-201AA (DO-27) axial-lead package, through-hole mount. The leaded format is well suited for point-to-point wiring or PCB insertion in power distribution modules.