TLP3052A(TP1,F

Toshiba Semiconductor

Toshiba Semiconductor TLP3052A(TP1,F), 1-channel non-zero-crossing triac optoisolator in 6-SMD gull-wing package, 600 V off-state, 5000 Vrms isolation, -40°C to 100°C

Toshiba Semiconductor TLP3052A(TP1,F
Download datasheet (PDF)
[IN STOCK] In Stock: 528 pcs
$1.11/ pc

Volume pricing

Buy Now

MOQ 1 · Tape & Reel (TR); Cut Tape (CT) · RoHS · EIA-481 · DAP/DDP · T/T

Technical specifications

TLP3052A(TP1,F specifications
Parameter / AttributeSpecification / Value
Output typeTriac
MountingSurface Mount
Voltage - isolation5000Vrms
Voltage - off state600 V
Voltage - forward (Vf)1.15V
Current - hold600µA (Typ)
Current - DC forward (If)50 mA
Current - LED trigger (Ift)10mA
Current - on state (It (RMS))100 mA
Operating temperature-40°C ~ 100°C
Approval agencyCQC, cUR, UR
PackageTape & Reel (TR); Cut Tape (CT)
Case6-SMD (5 Leads), Gull Wing
Channels1
Static dV (dt)2kV/µs (Typ)
Zero crossing circuitNo

Technical details

Triac optocoupler for 600 V AC line switching

The TLP3052A(TP1,F) is a 1-channel triac-output optoisolator from Toshiba, designed for driving medium-power AC loads like solenoids, valves, and small motors from a logic-level control side. Its 600 V off-state voltage suits 240 VAC mains applications with margin, and the 5000 Vrms isolation meets reinforced insulation requirements for safety-agency approval (CQC, cUR, UR per). This is a non-zero-crossing (random-phase) part, meaning the triac can be triggered at any point in the AC cycle — essential for phase-angle dimming, soft-start, or applications where zero-crossing switching would cause timing errors.

2 kV/µs dV/dt immunity and trigger current

A minimum static dV/dt of 2 kV/µs (typical,) ensures the output triac does not false-trigger on fast voltage transients from inductive load switching or mains noise — a common failure point in industrial environments. The LED trigger current (Ift) is 10 mA max, with a forward voltage of 1.15 V typical. On-state RMS current is rated at 100 mA max, and the holding current (Ih) is 600 µA typical — the minimum load current needed to keep the triac latched once triggered. Below this, the triac may drop out at the zero crossing, so the load must draw at least ~1 mA to stay on.

Active production in 6-SMD gull-wing package

Toshiba lists the TLP3052A(TP1,F) as Active and ROHS3 compliant. Cut Tape (CT) is also available for prototyping or low-volume builds. The package is a 6-SMD with 5 leads in gull-wing form, also referred to as 6-SO, 5 Lead. Surface-mount assembly with a standard reflow profile; no special MSL handling beyond typical moisture-sensitive device precautions.

TLP3052A(TP1,F
[ALLOC] verified
Quote