3.3 V fixed output, 3 A in a 3x3 mm QFN
The TPS62132RGTR: The DCS-Control topology keeps the switching frequency at 2.5 MHz, which lets the output filter use small inductors and ceramics — a common choice for space-constrained 3.3 V rails in industrial and telecom boards.
Switching frequency and inductor sizing
At 2.5 MHz, the typical inductor value drops to the 1 µH to 2.2 µH range, which fits a 2.0 mm or 2.5 mm footprint.