Load discharge and dual-channel flexibility
Each output includes a load discharge feature that pulls the output to ground when the switch is off, preventing floating rails on downstream loads. The two channels share a common bias supply but switch independently via separate On/Off inputs. The non-inverting input logic and 1:1 input-to-output ratio simplify integration into existing power-sequencing schemes.