Skip to main content
Texas Instruments OPA341UA/2K5 — Analog & Data Acquisition

OPA341UA/2K5 CMOS Op-Amp, 5.5 MHz, Rail-to-Rail Output

MPNOPA341UA/2K5
End of Life

Texas Instruments MicroAmplifier™ series, OPA341UA/2K5, CMOS op-amp, single circuit, 5.5 MHz gain bandwidth, 6 V/µs slew rate, rail-to-rail output, 2.5 V to 5.5 V supply, 750 µA supply current, 8-SOIC package, -55°C to 125°C.

$0.51Ref. price · indicative, final on quote
Packaging8-SOIC (0.154", 3.90mm Width)
RoHSNot applicable
SeriesMicroAmplifier™
Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

OPA341UA/2K5 specifications
ParameterValue
SeriesMicroAmplifier™
Output typeRail-to-Rail
MountingSurface Mount
Amplifier typeCMOS
Voltage - input offset2 mV
Voltage - supply span5.5 V
Current - supply750µA
Current - input bias0.6 pA
Current - output (Channel)50 mA
Operating temperature-55°C ~ 125°C
Gain bandwidth product5.5 MHz
PackageBulk
Slew rate6V/µs
Case8-SOIC (0.154\", 3.90mm Width)
Number of circuits1

Product details

Single-supply CMOS op-amp with rail-to-rail output

The rail-to-rail output stage maximizes dynamic range when driving ADCs or buffering signals in single-supply systems. With an input bias current of 0.6 pA, it suits high-impedance sensor interfaces such as photodiode amplifiers and pH probe buffers.

750 µA supply current — the power budget decision

At 750 µA typical supply current, this op-amp sits in the low-power tier for a 5.5 MHz GBW device. For battery-operated field transmitters or portable instrumentation, that quiescent draw directly sets the runtime budget. The 50 mA output current per channel provides enough drive for headphone outputs or to swing the input of a successive-approximation ADC without an external buffer.

Military temperature range — deployment context

In avionics, the cold end covers -55°C soak during high-altitude cruise; the 125°C upper limit handles engine-bay or satellite internal heat. The CMOS input stage maintains the 0.6 pA bias current across temperature, critical for precision sensor conditioning where leakage would otherwise swamp the signal.

Frequently asked questions

Is OPA341UA/2K5 rail-to-rail?

Yes, the output stage is rail-to-rail. The input common-mode range, however, is not rail-to-rail — it extends from the negative rail to approximately 1 V below the positive rail.

What is the difference between OPA341UA and OPA341UA/2K5?

The die and electrical specifications are identical. The /2K5 suffix denotes tape-and-reel packaging in quantities of 2500 units per reel, while the base OPA341UA typically ships in tubes or smaller reel quantities. For high-volume automated assembly, the /2K5 variant is the standard ordering option.