Accuracy and resolution that define the measurement chain
The LM95235DIMM/NOPB delivers ±2°C local accuracy across the 25°C to 100°C test range, with a wider ±6°C limit at the extremes — this is the spec that determines whether the part holds calibration in a production test fixture or an environmental chamber. The 10-bit local resolution gives 0.125°C per LSB, while the remote channel runs 12-bit at 0.0625°C per LSB, meaning the external diode measurement sees finer temperature steps than the on-die reading.
Supply rail and interface — what the bus needs
The SMBus output means it shares a two-wire bus with other SMBus slaves; the protocol includes timeout and packet error checking that I²C lacks, so it is the right choice for noisy backplanes or long traces. The feature set includes One-Shot mode for a single conversion on demand, a programmable limit comparator that can assert an output switch without polling, and both shutdown and standby modes to cut supply current between readings — useful in battery-powered loggers or thermal management loops that only need periodic updates.
Package and board integration
Supplied in an 8-VSSOP package (3.00 mm width, 0.118-inch pitch), surface-mount only. The 8-MSOP and 8-TSSOP footprints are interchangeable for this part — both are listed as acceptable package/case options. Tape & Reel or Cut Tape packaging means it feeds into a pick-and-place without manual handling.
Lifecycle and compliance — no end-of-life surprises
The ROHS3 status covers the EU RoHS exemption list through 2026, so it ships into European builds without a waiver.