10 mV/°C output — no scaling, no math
The LM35CH/NOPB outputs 10 mV per degree Celsius. At 25°C the output is 250 mV; at 100°C it's 1.0 V. No external scaling resistors or gain stage are needed — feed it straight into a 0-1V ADC input and read the temperature directly. Accuracy is ±1°C at 25°C, typical for the LM35 family. The analog voltage output means the system's ADC resolution and reference determine the final measurement precision — a 10-bit ADC gives about 0.5°C per LSB at this scale.
TO-46 metal can — hermetic, board-mount ready
Supplied in Bulk — loose tubes or trays, not tape-and-reel. For automated pick-and-place, plan for tube feeders or manual kitting. The through-hole leads require wave soldering or hand-solder assembly; no reflow profile is needed.
Industrial temperature range — -40°C to 110°C
Rated for -40°C to 110°C ambient. This covers most industrial enclosures, engine compartments, and outdoor telecom cabinets. The 4V to 30V supply range means it works on common 5V, 12V, or 24V rails without a separate regulator.