5000Vrms isolation in a single-channel unidirectional isolator
It supports data rates up to 100Mbps with typical rise/fall times of 1.8ns and 1.9ns, making it suitable for high-speed signal isolation in industrial fieldbuses, motor drives, and isolated SPI interfaces.
85kV/µs CMTI — why it matters for motor-drive and inverter designs
With a minimum common-mode transient immunity of 85kV/µs, the ISO7710DWR maintains data integrity across the isolation barrier even when high-voltage switching transients couple into the bus. This is a critical parameter for systems with fast-switching SiC or GaN power stages, where common-mode voltage slew rates can exceed 50kV/µs. The 16ns maximum propagation delay (both directions) keeps timing jitter low enough for most control-loop applications.
The 5000Vrms isolation rating is maintained across the full temperature range, so no derating is needed for high-temperature operation.