Texas Instruments INA125U — Logic ICs

Texas Instruments INA125U Instrumentation Amplifier, 150 kHz

MPNINA125U
End of Life

Texas Instruments INA125U, single-channel instrumentation amplifier, 150 kHz bandwidth, 0.2 V/µs slew rate, 50 µV offset, 2.7–36 V supply, -40 to 85°C, 16-SOIC package.

$8.93Ref. price · indicative, final on quote
Packaging16-SOIC (0.154", 3.90mm Width)
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

INA125U Technical Specifications
ParameterValue
Mounting typeSurface Mount
Amplifier typeInstrumentation
Voltage - input offset50 µV
Voltage - supply span2.7 V
Current - supply460µA
Current - input bias10 nA
Current - output (Channel)12 mA
Operating temperature-40°C ~ 85°C
-3db bandwidth150 kHz
PackageTube
Slew rate0.2V/µs
Case16-SOIC (0.154\", 3.90mm Width)
Number of circuits1

Product details

Precision bridge amplifier for industrial sensing

The INA125U: Its 50 µV input offset voltage and 10 nA input bias current let it resolve microvolt-level signals from strain gauges, bridge sensors, and thermocouple outputs without the offset drift you'd get from a general-purpose op-amp.

Bandwidth and slew — signal conditioning, not fast acquisition

The 150 kHz bandwidth and 0.2 V/µs slew rate tell you this is a DC-to-low-frequency part. It is sized for precision bridge excitation and readout, thermocouple amplifiers, and industrial process-control loops — not for audio or high-speed data conversion front ends. The 460 µA supply current keeps it friendly for loop-powered transmitters.

Package and rework — 16-SOIC, no surprises

It reflows cleanly with a standard profile; no exposed pad to worry about. Tube shipment means the parts arrive with leads protected, but they come out of the tube with a static-dissipative handling step.

Frequently asked questions

What is the INA125U used for?

It is a precision instrumentation amplifier used for bridge sensor readout, strain gauge amplification, thermocouple conditioning, and industrial process-control signal chains where low offset and low drift matter.