Single-cell Li-Ion charger with USB input and 1.5A capacity
Charge current, timer, and fault protection
The charge current is constant and programmable via an external resistor; a programmable timer terminates the charge cycle after a set period. Built-in fault protection covers over-temperature, reverse current, and short-circuit conditions — no external monitoring components needed for these safeguards.