Skip to main content
TDK Corporation ACM2012-201-2P-T001 — EMI Filters & Ferrite Beads

TDK ACM2012-201-2P-T001 Common Mode Filter, 200 Ω, 350 mA

MPNACM2012-201-2P-T001
Active

TDK Corporation ACM series common mode filter, 2-line, 200 Ohms @ 100 MHz, 350 mA, 50 VDC, 250 mOhm DCR, -40°C ~ 105°C, Horizontal 4 PC Pad, 2.00mm x 1.20mm, ACM2012-201-2P-T001.

$1.5100Ref. price · indicative, final on quote
Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ACM2012-201-2P-T001 specifications
ParameterValue
SeriesACM
Filter typeSignal Line
MountingSurface Mount
Voltage rating - DC50V
Current rating350mA
Impedance @ frequency200 Ohms @ 100 MHz
Operating temperature-40°C ~ 105°C
Height0.051\" (1.30mm)
Size (Dimension)0.079\" L x 0.047\" W (2.00mm x 1.20mm)
PackageTape & Reel (TR) Cut Tape (CT)
CaseHorizontal, 4 PC Pad
Number of lines2
DC resistance (DCR)250mOhm

Product details

200 Ω common-mode impedance at 100 MHz — the insertion loss budget

The ACM2012-201-2P-T001: Rated 200 Ω @ 100 MHz common-mode impedance, this two-line filter targets signal-line EMI suppression on differential pairs — think USB, CAN, LVDS, or audio lines where common-mode noise couples into the cable shield or ground loop. Rated for 50 VDC continuous, the filter handles typical signal-line voltages with ample margin — the limiting factor is the current, not the voltage, in most differential interfaces.

Horizontal 4-pad footprint for tight board stacking

The Tape & Reel (TR) option supports volume pick-and-place; Cut Tape (CT) is available for prototype or low-volume builds without committing to a full reel.

Industrial temperature range for outdoor and enclosure use

Specified from -40°C to 105°C, the filter operates reliably in outdoor telecom cabinets, automotive cabin environments, or factory-floor enclosures where ambient temperatures climb without active cooling.

Frequently asked questions

Where can I buy the TDK ACM2012-201-2P-T001?

The ACM2012-201-2P-T001 is sourced to order against your BOM quantity through independent distribution.

What is the impedance of the ACM2012-201-2P-T001 at 100 MHz?

The common-mode impedance is 200 Ω at 100 MHz, typical for filtering conducted EMI on differential signal lines like USB, CAN, or LVDS.