The 95 ns trr is the parameter that determines switching losses at line-frequency hard-switching; a slower recovery diode would push the junction temperature above the 175 °C maximum under full load in a 100 kHz PFC stage.
600 V / 5 A — the power envelope
Rated for 600 V reverse voltage and 5 A average rectified current, this diode handles the voltage stress on the secondary side of a 400 V DC bus PFC stage with margin. The forward voltage drop is 1.3 V at 5 A — that 6.5 W conduction loss at full load dictates the heatsink requirement, not the junction limit. The TO-220 Full Pack package (TO-220FPAC) has an isolated tab, so the heatsink mounts directly without an insulating pad, saving assembly steps.
The part carries ROHS3 compliance, so it clears the material-restriction gate for new designs shipping into EU and UK markets.