40 ns fast recovery in a TO-220AC power package
Packaged in the through-hole TO-220AC case, it is designed for output rectification, freewheeling, and snubber clamping in switched-mode power supplies, PFC stages, and DC-DC converters where reverse-recovery losses must be minimized.
Obsolete — sourcing via surplus and broker channels
No last-time-buy window remains open through the factory. Procurement for this order code now depends on surplus inventory held by independent distributors and brokers. Buyers should verify date-code freshness and packaging condition — sealed factory reels with consistent date-codes are preferred over mixed-date auction lots.
Forward drop and thermal budget at 20 A
At the full 20 A rated current the forward voltage is 1.1 V, producing a conduction loss of 22 W. The 10 µA reverse leakage at 200 V is a room-temperature typical; leakage doubles roughly every 10 °C rise, so at elevated junction temperatures the leakage contribution to standby loss should be checked against the application's idle budget.