Skip to main content
STMicroelectronics STTH1602CG-TR — Discrete Semiconductors

STTH1602CG-TR Fast Recovery Diode

MPNSTTH1602CG-TR
Active

STMicroelectronics STTH1602CG-TR, Fast Recovery Diode Array, 1 Pair Common Cathode, 200V, 10A per diode, 26ns trr, 1.1V Vf at 8A, D2PAK (TO-263), Surface Mount, 175°C Junction.

$1.3100Ref. price · indicative, final on quote
PackagingTO-263-3, D²Pak (2 Leads + Tab), TO-263AB
RoHSROHS3 Compliant
Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

STTH1602CG-TR specifications
ParameterValue
MountingSurface Mount
Voltage - DC reverse (Vr)200 V
Voltage - forward (Vf) (Max) @ if1.1 V @ 8 A
Current - reverse leakage @ vr6 µA @ 200 V
Current - average rectified (Io) (per diode)10A
Operating temperature - junction175°C (Max)
SpeedFast Recovery =< 500ns, > 200mA (Io)
PackageTape & Reel (TR) Cut Tape (CT)
TechnologyStandard
CaseTO-263-3, D²Pak (2 Leads + Tab), TO-263AB
Diode configuration1 Pair Common Cathode
Reverse recovery time26 ns

Product details

The reverse recovery time is 26 ns.

10 A per die, common-cathode — the BOM-fit decision

Each of the two diodes in the common-cathode pair is rated for 10 A average rectified current. The forward voltage is 1.1 V maximum at 8 A.

175°C junction and 6 µA leakage — thermal design inputs

The junction is rated to 175°C maximum. Reverse leakage is 6 µA at 200 V.

D2PAK footprint and surface-mount assembly

The part comes in a D2PAK (TO-263-3) package — a 2-lead plus tab surface-mount package. The exposed tab is the anode of both diodes (common cathode on the leads), and it is also the primary thermal path.

STMicroelectronics lists the STTH1602CG-TR as Active. The ROHS3 compliance is confirmed. The base product number is STTH1602, so any future die revisions or package variants will carry a suffix change, not a full part-number obsoletion.

Frequently asked questions

What is the reverse recovery time of STTH1602CG-TR?

The reverse recovery time (trr) is 26 ns. This is the time from zero-crossing to when the reverse current decays to 10% of its peak value — the key parameter for switching loss in a hard-switched converter.