Skip to main content
STMicroelectronics BTB06-600BWRG — Memory (DRAM / SRAM / Flash / EEPROM)

ST BTB06-600BWRG Snubberless Triac, 600V 6A TO-220

MPNBTB06-600BWRG
End of Life

STMicroelectronics BTB06-600BWRG, Snubberless™ series, Alternistor - Snubberless triac, Single configuration, 600 V off-state, 6 A RMS on-state, Through Hole, TO-220-3 package, -40°C to 125°C junction temperature.

$1.54Ref. price · indicative, final on quote
PackagingTO-220-3
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

BTB06-600BWRG Technical Specifications
ParameterValue
SeriesSnubberless™
Triac typeAlternistor - Snubberless
Mounting typeThrough Hole
Voltage - off state600 V
Voltage - gate trigger (Vgt)1.3 V
Current - hold (Ih)50 mA
Current - gate trigger (Igt)50 mA
Current - on state (It (RMS))6 A
Current - non rep. surge 50, 60Hz60A, 63A
Operating temperature-40°C ~ 125°C (TJ)
PackageTube
ConfigurationSingle
CaseTO-220-3

Product details

Snubberless™ Alternistor — what it saves you

The STMicroelectronics BTB06-600BWRG is a Snubberless™ Alternistor triac rated for 600 V off-state and 6 A RMS on-state current in a TO-220-3 through-hole package. The Snubberless construction means the internal structure is designed to commutate inductive loads without an external RC snubber network — one less component to qualify, one less failure point on the board. Junction temperature range of -40°C to 125°C covers industrial enclosures and outdoor cabinets.

6 A continuous, 60 A surge — sizing the load

At 6 A RMS continuous, this triac handles small motors, resistive heaters, solenoid valves, and lighting banks. The non-repetitive surge rating of 60 A at 50 Hz and 63 A at 60 Hz covers lamp inrush and motor start transients.

Active production — no LTB clock ticking

The BTB06-600BWRG is listed as Active in production with ROHS3 compliance. No last-time-buy notice or end-of-life announcement is on record for this order code. For dual-sourcing flexibility, the BTA06-600BWRG is a functional equivalent — same Snubberless Alternistor construction, same 600 V / 6 A ratings, same TO-220 package — differing only in the BTA vs BTB prefix (typically the BTA variant has isolated tab, the BTB has non-isolated tab; verify your heatsinking approach before swapping).

Mounting and thermal — TO-220 tab isolation

Through-hole TO-220-3 package. The tab is electrically connected to the MT2 terminal — if you bolt it to a grounded heatsink, use an insulating pad and bushing. The Snubberless design means no snubber resistor-capacitor pair across the triac, but you still need a gate drive circuit capable of sourcing 50 mA peak.

Frequently asked questions

Is BTB06-600BWRG a direct replacement for BTB06-600BW?

Not without checking the gate drive and load type. The BWRG is Snubberless and can replace a standard triac in most inductive-load applications, but verify the gate trigger current (50 mA max) and hold current (50 mA) match your circuit. If the original design used a snubber, you can often remove it with the BWRG.

What is the closest functional second-source for BTB06-600BWRG?

The BTA06-600BWRG is the closest functional equivalent — same Snubberless Alternistor construction, same 600 V / 6 A ratings, same TO-220 package. The BTA prefix typically indicates an isolated tab; the BTB prefix is non-isolated. Verify heatsinking isolation before substituting.